18-142
hcsplt0
31
30
spltena
RW 0x0
15
14
xactpos
RW 0x0
hcsplt0 Fields
Bit
31
spltena
16
compsplt
15:14
xactpos
13:7
hubaddr
Altera Corporation
29
28
27
26
13
12
11
10
hubaddr
RW 0x0
Name
The application sets this field to indicate that this
channel is enabled to perform split transactions.
0x0
0x1
The application sets this field to request the OTG host
to perform a complete split transaction.
Value
0x0
0x1
This field is used to determine whether to send all,
first, middle, or last payloads with each OUT transac‐
tion.
Value
0x0
0x1
0x2
0x3
This field holds the device address of the transaction
translator's hub.
Bit Fields
25
24
23
22
Reserved
9
8
7
6
Description
Value
Description
Split not enabled
Split enabled
Description
No split transaction
Split transaction
Description
Mid. This is the middle payload of this
transaction (which is larger than 188 bytes)
End. This is the last payload of this transac‐
tion (which is larger than 188 bytes)
Begin. This is the first data payload of this
transaction (which is larger than 188 bytes)
All. This is the entire data payload is of this
transaction (which is less than or equal to 188
bytes)
21
20
19
18
5
4
3
2
prtaddr
RW 0x0
Access
USB 2.0 OTG Controller
cv_5v4
2016.10.28
17
16
compsplt
RW 0x0
1
0
Reset
RW
0x0
RW
0x0
RW
0x0
RW
0x0