Quanta Computer QuantaMesh User Manual page 437

Layer 2/3/4 managed switch
Table of Contents

Advertisement

UANTA COMPUTER INC.
5.12.2.7 lldp timers
This command is used to set the timing parameters for local data transmission on ports enabled for
LLDP. The <interval-seconds> determines the number of seconds to wait between transmitting local
data LLDPDUs. The range is 1-32768 seconds. The <hold-value> is the multiplier on the transmit
interval that sets the TTL in local data LLDPDUs. The multiplier range is 2-10. The <reinit-seconds> is
the delay before re-initialization, and the range is 1-0 seconds.
Syntax
lldp timers [interval <interval-seconds>] [hold <hold-value>] [reinit <reinit-seconds>]
no lldp timers [interval] [hold] [reinit]
<interval-seconds> - Configures the number of seconds to wait between transmitting local data
LLDPDUs
<hold-value> - Configures the multiplier on the transmit interval that sets the TTL in local data
LLDPDUs
<reinit-seconds> - Configures the delay before re-initialization
no - This command is used to return any or all timing parameters for local data transmission on ports
enabled for LLDP to the default values.
Default Setting
Interval-seconds 30
Hold-value 4
Reinit-seconds 2
Command Mode
Global Config
Layer 2/3/4 Managed Switch
QuantaMesh | Switching Commands
437

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QuantaMesh and is the answer not in the manual?

Table of Contents

Save PDF