5.11.2.8 sntp clock timezone
This command sets the time zone for the switch's internal clock.
Syntax
sntp clock timezone <name> <0-12> <0-59> {before-utc | after-utc}
<name> - Name of the time zone, usually an acronym. (Range: 1-15 characters)
<0-12> - Number of hours before/after UTC. (Range: 0-12 hours)
<0-59> - Number of minutes before/after UTC. (Range: 0-59 minutes)
before-utc - Sets the local time zone before (east) of UTC.
after-utc - Sets the local time zone after (west) of UTC.
Default Setting
Taipei 08:00 After UTC
Command Mode
Global Config
5.11.2.9 sntp multicast client poll-internal
This command will set the poll interval for SNTP multicast clients in seconds.
Syntax
sntp multicast client poll-interval <poll-interval>
no sntp multicast client poll-interval
<poll-interval> - Polling interval. It's 2^(value) seconds where the range of value is 6 to 10.
no – This command will reset the poll interval for SNTP multicast client to its default value.
Default Setting
The default value is 6.
Command Mode
Global Config