for PE are stored in the following directory: flash://default_diag_report_dir.
To view the test report, use the show file flash://filename command.
Command History
This guide is platform-specific. For command information about other platforms, see
the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version
9.9(0.0)
9.2(1.0)
8.3.19.0
8.3.11.1
8.3.7.0
8.3.1.0
7.7.1.0
Example
Dell#offline stack-unit 3
Warning - offline of unit will bring down all the protocols and
the unit will be operationally down, except for running
Diagnostics.
Please make sure that stacking is not configured for Diagnostics
execution.
If configured, the unit roles may change. The unit will become
standalone once diags are executed.
Also reboot/online command is necessary for normal operation
after the offline command is issued.
Proceed with Offline [confirm yes/no]:yes
Dell#diag stack-unit 3 level0
Warning - diagnostic execution will cause multiple link flaps on
the peer side - advisable to shut directly connected ports
Proceed with Diags [confirm yes/no]: yes
Related
•
Commands
•
Description
Introduced on C9010 and C1048P.
Introduced on the Z9500.
Introduced on the S4820T.
Introduced on the Z9000.
Introduced on the S4810.
Introduced the verbose option.
Introduced on the S-Series.
offline
online
PE Console Commands
1614