Dell C9000 Series Reference Manual page 1613

Networking command-line reference guide
Hide thumbs Also See for C9000 Series:
Table of Contents

Advertisement

level1
level2
interactive
testname name
terminate
Defaults
All offline diagnostic tests are run on all switch CPUs (Control Processor, Route
Processor, and line cards).
Command Modes
EXEC Privilege
Usage Information Before you use this command to run diagnostic test, make sure that the port extender
(PE) stack-unit is offline (offline stack-unitunit number command). You are
prompted to reboot when the offline diagnostics is complete.
The PE unit goes offline and reboots automatically after the test is completed. Once the
test is finished, the diag report is generated, and it is stored in the PE flash. To view the
diag report, use the show diag pe pe-id stack-unit unit-number command
from C9000 system. The show diag pe command uploads the TestReport from the
PE to the C9000.
The filename of the TestReport is:TestReport-SU-Stack-Unit-Number-PE-pe-
id-Year_Month_Day_Unique-Tag.txt, where SU identifies the PE stack-unit on
which the offline diag test was run, Year_Month_Day is a timestamp to identify when
the offline diag test was run for that unit, and the Unique Tag is to identify that
specific diag test. Diag test reports on PE are not overwritten. Offline diag test reports
Enter the keyword Level1 to run Level 1 diagnostics. Level 1
diagnostics is a smaller set of diagnostic tests with support for
automatic partitioning. They perform status/self test for all the
components on the board and test their registers for appropriate
values. In addition, they perform extensive tests on memory
devices (for example, SDRAM, flash, NVRAM, EEPROM, and
CPLD) wherever possible. At this level, ports are shut down
automatically.
Enter the keyword level2 to run Level 2 diagnostics. Level 2
diagnostics are a full set of diagnostic tests with no support for
automatic partitioning. Level 2 diagnostics are used primarily for
on-board loopback tests and more extensive component
diagnostics. Various components on the board are put into
Loopback mode and test packets are transmitted through those
components. These diagnostics also perform snake tests using
VLAN configurations.
Enter the keyword interactive to run offline diagnostics in
interactive mode.
NOTE:
On a C1048P, interactive diagnostic tests are
supported only in standalone mode; they are not
supported in stacking mode.
Enter the testname name parameters to run a specified offline
diagnostic test. Enclose the test-case name in double quotes
(" "). For example: diag level1 testname "first".
Enter the keyword terminate to stop the offline diagnostic
tests that are running.
PE Console Commands
1613