13
TRACe Subsystem
TRACe[1]|2:MEASurement:PULSe[1]|...|10:SEParation?
This command returns the time difference of the n
trace. As power pulses are by definition positive pulses, the pulse separation is the
time difference between negative transition of one pulse and the positive
transition of the next pulse.
Algorithm
If the first transition in the trace is positive,
then
PULSe:SEParation = time the second positive transition occurs -time the first
negative transition occurs
else
PULSe:SEParation = time the first positive transition occurs -time the first
negative transition occurs.
Syntax
Example
626
TRAC
1
2
TRAC1:MEAS:PULS:SEP?
:MEAS
:PULS
This command returns the time separation of
the 1st and 2nd pulses found on trace 1.
N1911A/1912A P-Series Power Meters Programming Guide
th
th
and (n+1)
pulses found on a
1
:SEP
2|...|10
?