Keysight X-Series Signal Analyzers
This manual provides documentation for the following models:
PXA Signal Analyzer N9030A
MXA Signal Analyzer N9020A
EXA Signal Analyzer N9010A
CXA Signal Analyzer N9000A
N9083A & W9083A
Multi-Standard
Radio Measurement
Application
Measurement Guide

Advertisement

Table of Contents
loading

Summary of Contents for Keysight X Series

  • Page 1 Keysight X-Series Signal Analyzers This manual provides documentation for the following models: PXA Signal Analyzer N9030A MXA Signal Analyzer N9020A EXA Signal Analyzer N9010A CXA Signal Analyzer N9000A N9083A & W9083A Multi-Standard Radio Measurement Application Measurement Guide...
  • Page 2 PERFORMANCE OF THIS to the public to use, modify, DOCUMENT OR ANY INFORMATION reproduce, release, perform, CONTAINED HEREIN. SHOULD display, or disclose commercial KEYSIGHT AND THE USER HAVE A computer software or SEPARATE WRITTEN AGREEMENT commercial computer software WITH WARRANTY TERMS...
  • Page 3 To receive the latest updates by email, subscribe to Keysight Email Updates at the following URL: http://www.keysight.com/find/MyKeysight Information on preventing instrument damage can be found at: www.keysight.com/find/PreventingInstrumentRepair Is your product software up-to-date? Periodically, Keysight releases software updates to fix known defects and incorporate product enhancements. To search for software updates for your product, go to the Keysight Technical Support website at: http://www.keysight.com/find/techsupport...
  • Page 5: Table Of Contents

    Carrier Power Measurement Bandwidth and Filter......67 Keysight NxxxxX Installation Guide...
  • Page 6 Instrument Updates at www.keysight.com ........
  • Page 7: About The Msr Measurement Application

    Keysight X-Series Signal Analyzers N9083A & W9083A Multi-Standard Radio Measurement Application Measurement Guide About the MSR Measurement Application This chapter provides overall information on MSR (Multi-Standard Radio) communications systems, and describes MSR measurements made by the analyzer. What Does the MSR Application Do?
  • Page 8 CDMA 1xEVDO Measurement Application TD-SCDMA N/W9079A-1FP TD-SCDMA Measurement Application — If you need to make valid measurements on Multi-Standard Radio signal bandwidths greater than 10 MHz, WB (25MHz or wider) option needs to be installed in PXA/MXA/EXA/CXA. Keysight N9083A & W9083A Measurement Guide...
  • Page 9: Making Msr Measurements

    Keysight X-Series Signal Analyzers N9083A & W9083A Multi-Standard Radio Measurement Application Measurement Guide Making MSR Measurements This chapter begins with instructions common to all measurements including equipment configuration, simple steps for making a measurement, then details how to make the measurements available by pressing the MSR mode and Meas key for MSR Downlink signal.
  • Page 10: Setting Up And Making A Measurement

    Meas Setup c. Press Use Meas Setup to make any required adjustment to the selected measurement settings. The settings only apply to this measurement. Keysight N9083A & W9083A Measurement Guide...
  • Page 11 2. Select and set up a measurement. Restart Single Cont View/Display SPAN X Scale Peak Search, 3. Select and set up a view of the results. AMPTD Y Scale Quick Save Save Recall File Print Keysight N9083A & W9083A Measurement Guide...
  • Page 12: Msr Downlink Signal Measurement

    1. Connect the RF Output of the Signal Generator to the Input port of the Component. 2. Connect the Output port of the Component to the RF Input of the Signal Analyzer. Base Station Measurement System See the connection of the equipment below. Keysight N9083A & W9083A Measurement Guide...
  • Page 13 Making MSR Measurements MSR Downlink Signal Measurement Figure 2-2 Base Station Test System Connect the RF Output of the BTS to the RF Input of the analyzer using the appropriate attenuator. Keysight N9083A & W9083A Measurement Guide...
  • Page 14: Setting The Downlink Signal

    MSR Downlink Signal Measurement Setting the Downlink Signal In this example, the test signal is created according to MSR test configuration TC4c of standard 3GPP TS 37.141. Keysight Signal Studio N7624B, is used to generate the MSR waveform for testing. Figure 2-3...
  • Page 15 Making MSR Measurements MSR Downlink Signal Measurement Figure 2-4 N7624B Signal Studio Configuration (MSR Downlink Signal) Keysight N9083A & W9083A Measurement Guide...
  • Page 16: Common Measurement Procedure (Downlink)

    Configure Carriers to manually configure the and Max GSM/EDGE Carriers. carriers. Select 5 MHz (default value) for LTE FDD BW. In LTE FDD Location, select Upper (Higher than W-CDMA) (default value) for the location of LTE FDD carriers. Keysight N9083A & W9083A Measurement Guide...
  • Page 17: Monitor Spectrum Measurements

    Number, On , enter a number (such displaying texts for Carrier 1 and 6, only as 50) using the front-panel keypad. vertical lines and arrows are displayed. The measurement result should look Figure 2-5 like Keysight N9083A & W9083A Measurement Guide...
  • Page 18 5. Select the Carrier Info Press view. Info . This view contains the spectrum trace and the carriers information table, Figure 2-6 . You can choose to display offset or absolute frequency under the menu Carrier Info. Keysight N9083A & W9083A Measurement Guide...
  • Page 19 If you have a problem, and get an error message, see the guide “Instrument Messages”, which is provided on the Documentation CD ROM, and in the instrument here: C:\Program Files\Keysight\SignalAnalysis\Infrastructure\Help\bookfiles. Keysight N9083A & W9083A Measurement Guide...
  • Page 20: Iq Waveform (Time Domain) Measurements

    RF Envelope with the current data. The measurement. measured values for the mean power and peak-to-mean power are shown in the text window. Figure 2-7 MSR Downlink IQ Waveform Measurement Result - RF Envelope View Keysight N9083A & W9083A Measurement Guide...
  • Page 21 If you have a problem, and get an error message, see the guide “Instrument Messages”, which is provided on the Documentation CD ROM, and in the instrument here: Keysight N9083A & W9083A Measurement Guide...
  • Page 22 Making MSR Measurements MSR Downlink Signal Measurement C:\Program Files\Keysight\SignalAnalysis\Infrastructure\Help\bookfiles. Keysight N9083A & W9083A Measurement Guide...
  • Page 23: Channel Power Measurements

    3. Select Carrier Info view. View/Display Carrier You can choose to display offset or absolute Press frequency under the menu Carrier Info. Info . This view contains the spectrum trace and the carriers information table, Figure 2-10 Keysight N9083A & W9083A Measurement Guide...
  • Page 24 Figure 2-10 MSR Downlink Channel Power Measurement Result - Carrier Info View 4. (Optional) Display the View/Display Bar Graph The Bar Graph view result should look like Press Channel Power Bar Figure 2-11 Graph view. Keysight N9083A & W9083A Measurement Guide...
  • Page 25 If you have a problem, and get an error message, see the guide “Instrument Messages”, which is provided on the Documentation CD ROM, and in the instrument here: C:\Program Files\Keysight\SignalAnalysis\Infrastructure\Help\bookfiles. Keysight N9083A & W9083A Measurement Guide...
  • Page 26: Occupied Bandwidth Measurements

    Press Bandwidth vertical lines to indicate the various offset measurement. settings, and a measurement summary below. The Occupied BW measurement Figure 2-10 results should look like Figure 2-12 MSR Downlink Occupied BW Measurement Result Keysight N9083A & W9083A Measurement Guide...
  • Page 27 Any distortion such as harmonics or intermodulation, for example, produces undesirable power outside the specified bandwidth. Shoulders on either side of the spectrum shape indicate spectral regrowth and intermodulation. Rounding or sloping of the top shape can indicate filter shape problems. Keysight N9083A & W9083A Measurement Guide...
  • Page 28: Acp Measurements

    ,a file open dialog appears. recalled. In this example, Select the appropriate file under ACP_BS_MSR_Carr_both_5MHz_pairE-UTRA_ masks\ACP_BS and click open. This will both_5MHz_CarB.mask is used. apply the Offset/Limit settings quickly. The other parameters will not be changed. Keysight N9083A & W9083A Measurement Guide...
  • Page 29 To correctly use the Noise Correction feature, you MUST re-calibrate the correction (set to Off, then On) after ANY measurement parameters are changed. Failure to re-calibrate the Noise Correction will provide invalid data. When Noise Correction is On, the screen annotation NCORR is shown below the Input. Keysight N9083A & W9083A Measurement Guide...
  • Page 30 If you have a problem, and get an error message, see the guide “Instrument Messages”, which is provided on the Documentation CD ROM, and in the instrument here: C:\Program Files\Keysight\SignalAnalysis\Infrastructure\Help\bookfiles. Keysight N9083A & W9083A Measurement Guide...
  • Page 31: Spectrum Emission Mask Measurements

    Offset/Limit settings quickly. The other parameters will not be changed. At the bottom of the screen, there is a message to indicate which mask file is recalled. In this example, SEM_BS_MSR_BC2.mask is used. Keysight N9083A & W9083A Measurement Guide...
  • Page 32 — For Abs AND Rel mask, the Lower or Upper Lim is compared with the higher limit line. — For Abs OR Rel mask, the Lower or Upper Lim is compared with the lower limit line. Keysight N9083A & W9083A Measurement Guide...
  • Page 33 Figure 2-16 information table, see . You can choose to display offset or absolute frequency under the menu Carrier Info. Figure 2-16 MSR Downlink Spectrum Emission Mask Measurement Result - Carrier Info View Keysight N9083A & W9083A Measurement Guide...
  • Page 34 Since spectrum emission mask measures the spectral response of the amplifier to a complex wideband signal, it is a key measurement linking amplifier linearity and other performance characteristics to the stringent system specifications. Keysight N9083A & W9083A Measurement Guide...
  • Page 35: Spurious Emissions Measurement

    However, the table always shows the last reported trace information. Press Restart to update the table to show the latest result. Keysight N9083A & W9083A Measurement Guide...
  • Page 36 MSR Downlink Spurious Emissions Measurement - Spur Table Figure 2-18 You can use the window control keys below the screen to zoom the result screen. See Figure 2-18 MSR Downlink Spurious Emissions Measurement - Numeric Result Screen Keysight N9083A & W9083A Measurement Guide...
  • Page 37 If you have a problem, and get an error message, see the guide “Instrument Messages”, which is provided on the Documentation CD ROM, and in the instrument here: C:\Program Files\Keysight\SignalAnalysis\Infrastructure\Help\bookfiles. Keysight N9083A & W9083A Measurement Guide...
  • Page 38: Power Statistics Ccdf Measurements

    The Info BW is the channel bandwidth that will be used for data acquisition. You can manually change the Info BW under the BW menu. Figure 2-20 MSR Downlink Power Statistics CCDF Measurement Result Keysight N9083A & W9083A Measurement Guide...
  • Page 39 The default is If you have a problem, and get an error message, see the guide “Instrument Messages”, which is provided on the Documentation CD ROM, and in the instrument here: C:\Program Files\Keysight\SignalAnalysis\Infrastructure\Help\bookfiles. Keysight N9083A & W9083A Measurement Guide...
  • Page 40 For example, it can help determine the optimum operating point to adjust each code timing for appropriate peak or average power ratio, or both, for the transmitter. Keysight N9083A & W9083A Measurement Guide...
  • Page 41: Conformance Evm Measurement

    If you use a test model to do the measurement, the Recall function is provided for E-URTA Test Models (E-TM) to setup the LTE FDD parameters automatically. See ”Recall EVM setup.”. Keysight N9083A & W9083A Measurement Guide...
  • Page 42 This will apply the EVM settings quickly. The other parameters will not be changed. At the bottom of the screen, there is a message to indicate which mask file is recalled. In this example, LTEFDD-TM1.1-BW5MHz.fps is used. Keysight N9083A & W9083A Measurement Guide...
  • Page 43 Metrics Carrier Index then enter the carrier number you want to see. You can also scroll down the table to see the results for all the carriers. Figure 2-24 MSR Downlink Conformance EVM Result - Carrier4 Keysight N9083A & W9083A Measurement Guide...
  • Page 44 Avg/Hold Num. default condition. If you have a problem, and get an error message, see the guide “Instrument Messages”, which is provided on the Documentation CD ROM, and in the instrument here: C:\Program Files\Keysight\SignalAnalysis\Infrastructure\Help\bookfiles. Keysight N9083A & W9083A Measurement Guide...
  • Page 45: Concepts

    MSR signal to help you have better understanding of tests and do the measurements correctly and quickly. It contains the following sections: • “MSR Overview” on page 46 • “MSR Measurement Concepts” on page 53 • “Instrument Updates at www.keysight.com” on page 95...
  • Page 46: Msr Overview

    (BS) conformance testing (Release 10) — 3GPP TS 37.104 V9.2.0 (2010-12) E-UTRA, UTRA and GSM/EDGE; Multi-Standard Radio (MSR) Base Station (BS) transmission and reception (Release 9) The latest version of the 37-series documents can be found at http://www.3gpp.org/ftp/specs/archive/37_series/. Keysight N9083A & W9083A Measurement Guide...
  • Page 47: Band Category

    2110 MHz – 2170 MHz 1475.9 MHz – 1495.9 MHz 728 MHz – 746 MHz XIII 746 MHz – 756 MHz 758 MHz – 768 MHz Reserved Reserved 734 MHz – 746 MHz 1 ** Keysight N9083A & W9083A Measurement Guide...
  • Page 48: Rf Bandwidth

    Base station RF Bandwidth in continuous spectrum operation is defined as shown in the figure below. F and F denote center frequencies of C,low C,high lowermost and uppermost carriers respectively. F for each format is Offset,RAT Keysight N9083A & W9083A Measurement Guide...
  • Page 49 RF bandwidth might be smaller than the specified one. Spectrum Emission Mask measurement is done based on base station RF bandwidth. Base Station in non-contiguous operation has sub-blocks defined in 3GPP TS 37.141 as shown in the figure below: Keysight N9083A & W9083A Measurement Guide...
  • Page 50: Channel Raster

    If channel raster is 100 kHz, that means the carrier center frequency must be an integer multiple of 100 kHz. Channel raster of each format is listed below. E-UTRA (LTE): 100 kHz UTRA (W-CDMA, TD-SCDMA): 200 kHz GSM/EDGE: 200 kHz Keysight N9083A & W9083A Measurement Guide...
  • Page 51: Channel Spacing

    (E-UTRA FDD) (E-UTRA TDD) 4.8.1 TC1a/N 1, 2 TC1a 4.8.1 TC1b 4.8.2 1, 2, 3 /NTC2 4.8.3 TC3a/N 1, 2 TC3a 4.8.3 TC3b 4.8.4 TC4a/N TC4a 4.8.4 TC4b/N TC4b 4.8.4 TC4c/N TC4c 4.8.4 TC4d Keysight N9083A & W9083A Measurement Guide...
  • Page 52 Concepts MSR Overview Table 3-8 MSR Test Configuration 4.8.4 TC4e 4.8.5 TC5a/N TC5a 4.8.5 TC5b/N TC5b 4.8.5 NTC5c 4.8.6 TC6a 4.8.6 TC6b 1, 2 4.8.6 TC6c 1, 2, 3 Keysight N9083A & W9083A Measurement Guide...
  • Page 53: Msr Measurement Concepts

    “Carrier Power Measurement Bandwidth and Filter” on page 67 • “Offset/Limit Presets” on page 67 • “Carrier Info Table” on page 68 • “Carrier Conf Presets” on page 68 • “Format Parameter List in Mode Setup” on page 69 Keysight N9083A & W9083A Measurement Guide...
  • Page 54: Channel Power Measurement Concepts

    To improve repeatability, you can increase the number of averages. The channel power graph is shown in the graph window, while the absolute channel power in dBm and the mean power spectral density in dBm/Hz are shown in the text window. Keysight N9083A & W9083A Measurement Guide...
  • Page 55: Occupied Bandwidth Measurement Concepts

    FOffset,OBW value is based on the standard, the span is set to the one required by the standard for OBW test of corresponding format when only one carrier is detected by the auto detection. Keysight N9083A & W9083A Measurement Guide...
  • Page 56: Adjacent Channel Power (Acp) Measurement Concepts

    If PSD Ref (Power Spectral Density Reference) is selected, the results are displayed as relative power in dB, and as absolute power in dBm/Hz. Keysight N9083A & W9083A Measurement Guide...
  • Page 57: Power Statistics Ccdf Measurement Concepts

    The percent of time the signal spends at or above the level defines the probability for that particular power level. To make the power statistics CCDF measurement, the instrument uses digital signal processing (DSP) to sample the input signal in the channel bandwidth. Keysight N9083A & W9083A Measurement Guide...
  • Page 58 If the currently measured trace is above the user reference trace, it means that the higher peak power levels against the average power are included in the input signal. Keysight N9083A & W9083A Measurement Guide...
  • Page 59: Spurious Emissions Measurement Concepts

    Operating Band is None.Intermodulation test is supported in this measurement. The intermodulation interference frequency range specified by the parameters under the Intermod menu is excluded from the measurement when interference power present is on. Keysight N9083A & W9083A Measurement Guide...
  • Page 60: Spectrum Emission Mask Measurement Concepts

    Measure Carrier on are measured to determine the max power. For example, when Left & Right Carriers is selected, only the edge carriers are measured and displayed. Keysight N9083A & W9083A Measurement Guide...
  • Page 61 Each pair may be defined with unique measurement bandwidths. The results are displayed both as relative power in dBc, and as absolute power in dBm. The measurement supports the limit preset as described in “Offset/Limit Presets” on page Keysight N9083A & W9083A Measurement Guide...
  • Page 62: Iq Waveform Measurement Concepts

    The input analog signal is converted to a digital signal, which then is processed into a representation of a waveform measurement. The measurement relies on a high rate of sampling to create an accurate representation of a time domain signal. Keysight N9083A & W9083A Measurement Guide...
  • Page 63: Monitor Spectrum (Frequency Domain) Measurement Concepts

    The analyzer sweeps the LO to generate a heterodyned IF signal which can be detected for the purpose of analyzing the signal content of a range of frequencies. The x-axis of the display is frequency, the Y Axis is amplitude. Keysight N9083A & W9083A Measurement Guide...
  • Page 64: Msr Conformance Evm Measurement Concepts

    GSM/EDGE EDGE EVM No graphical view (such as I/Q Measured Polar Graph, I/Q Error, Data Bits) available. No limit judge functionality. Some SCPI commands in the original measurement are not available in this measurement. Keysight N9083A & W9083A Measurement Guide...
  • Page 65 Some SCPI commands in the original measurement are not available in this measurement. Some SCPI commands are newly added to this measurement. See “Format Parameter List in Mode Setup” on page 69 for details. TD-SCDMA Mod Accuracy Keysight N9083A & W9083A Measurement Guide...
  • Page 66 Some SCPI commands in the original measurement are not available in this measurement. Some SCPI commands are newly added to this measurement. See “Format Parameter List in Mode Setup” on page 69 for details. Keysight N9083A & W9083A Measurement Guide...
  • Page 67: Carrier Power Measurement Bandwidth And Filter

    XA FW which can be found under My Document/MSR folder. ACP, SEM and SPUR support Offset/Limit Preset. Parameters affect the limit preset is listed below. ACP: Assumed Adj Channels, Carriers, Carrier Offset, LTE FDD BW, Radio Format Keysight N9083A & W9083A Measurement Guide...
  • Page 68: Carrier Info Table

    It also provides presets for non standard carrier configuration which just puts single RAT carriers as many as allowed. Carrier Config Presets set up following parameters. Keysight N9083A & W9083A Measurement Guide...
  • Page 69: Format Parameter List In Mode Setup

    If you have a set of SCPI lists to set up the original measurement, you can easily convert it for this measurement by simply replacing the measurement node name with “RADio:FORMat:<Radio Format node>” as follows: Radio Format SCPI node in Original Radio Format node Measurement GSM/EDGE :EEVM :RADio:FORMat:GSM{List Index} Keysight N9083A & W9083A Measurement Guide...
  • Page 70 LTE FDD Format Parameter List Since most parameters are the same as those used in the original measurement, the SCPI commands in the original measurement can be used in this measurement by converting the measurement node. Keysight N9083A & W9083A Measurement Guide...
  • Page 71 The following SCPI commands in the LTE FDD Conformance EVM measurement are not available in this measurement. SCPI Command not available in this Measurement :DISPlay:CEVM:VIEW1|VIEW[:SELect] [:SENSe]:CEVM:AVERage:NUMber [:SENSe]:CEVM:AVERage:TCONtrol [:SENSe]:CEVM:BERate:FILE:FORMat [:SENSe]:CEVM:BERate:FILE:NAME [:SENSe]:CEVM:BERate:FILE:PATH [:SENSe]:CEVM:BERate:FILE:Q:NAME [:SENSe]:CEVM:BERate:FILE:SEParated [:SENSe]:CEVM:BERate:OSRatio [:SENSe]:CEVM:DLINk:DECode:DFINclude [:SENSe]:CEVM:DLINk:DECode:RNTI:MAXimum:RA [:SENSe]:CEVM:DLINk:DECode:RNTI:MAXimum:TPC [:SENSe]:CEVM:DLINk:DECode:RNTI:MINimum:RA [:SENSe]:CEVM:DLINk:DECode:RNTI:MINimum:TPC [:SENSe]:CEVM:DLINk:RESult [:SENSe]:CEVM:EVM:COPY[:IMMediate]/nquery/ [:SENSe]:CEVM:ULINk:BERate:DECoder:CONFigure Keysight N9083A & W9083A Measurement Guide...
  • Page 72 These commands above are not in the Format Parameter List. The preset of the following command differs between the LTE TDD CEVM and MSR CEVM. SCPI Command in LTE TDD CEVM SCPI Command in this measurement Preset in this measurement [:SENSe]:CEVM:MCFilter:STATe [:SENSe]:RADio:FORMat:LTETdd{1:3}:MCFilter:STATe Keysight N9083A & W9083A Measurement Guide...
  • Page 73 [:SENSe]:RADio:CONFigure:HSDPa[:STA [:SENSe]:RADio:FORMat:WCDMa{1:3}:CONFigure:HS DPa[:STATe] The following SCPI commands in the W-CDMA Mod Accuracy measurement are converted for this measurement as follows: SCPI Command in Mod Accuracy SCPI Command in this measurement [:SENSe]:RHO:AVERage:COUNt [:SENSe]:CEVM:WCDMa:AVERage:COUNt [:SENSe]:RHO:AVERage[:STATe] [:SENSe]:CEVM:WCDMa:AVERage[:STATe] Keysight N9083A & W9083A Measurement Guide...
  • Page 74 SCPI Command not available in this measurement :CALCulate:RHO:LIMit:CDERror :CALCulate:RHO:LIMit:CPICh[:BTS] :CALCulate:RHO:LIMit:CPICh[:BTS]:POWer :CALCulate:RHO:LIMit:FERRor :CALCulate:RHO:LIMit:PEAK :CALCulate:RHO:LIMit:RHO :CALCulate:RHO:LIMit:RMS :CALCulate:RHO:MARKer{1:12}:AOFF/nquery/ :CALCulate:RHO:MARKer{1:12}:CHIP :CALCulate:RHO:MARKer{1:12}:COUPle[:STATe] :CALCulate:RHO:MARKer{1:12}:CPEak[:STATe] :CALCulate:RHO:MARKer{1:12}:FUNCtion:RESult?/qonly/ :CALCulate:RHO:MARKer{1:12}:MAXimum/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:HIGHer/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:LEFT/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:LOWer/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:NEXT/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:RIGHt/nquery/ :CALCulate:RHO:MARKer{1:12}:MINimum/nquery/ :CALCulate:RHO:MARKer{1:12}:MODE :CALCulate:RHO:MARKer{1:12}:PTPeak/nquery/ :CALCulate:RHO:MARKer{1:12}:REFerence :CALCulate:RHO:MARKer{1:12}:STATe :CALCulate:RHO:MARKer{1:12}:TRACe :CALCulate:RHO:MARKer{1:12}:X :CALCulate:RHO:MARKer{1:12}:X:POSition :CALCulate:RHO:MARKer{1:12}:Y?/qonly/ :DISPlay:RHO:CDOMain:SPAN:STARt Keysight N9083A & W9083A Measurement Guide...
  • Page 75 MSR Measurement Concepts :DISPlay:RHO:CDOMain:SPAN:STOP :DISPlay:RHO:VIEW1|VIEW:NSELect :DISPlay:RHO:VIEW1|VIEW[:SELect] :DISPlay:RHO:VIEW1|VIEW:WINDow:TEXT:TFUNit :DISPlay:RHO:VIEW1|VIEW:WINDow2:TRACe:COFFset :DISPlay:RHO:VIEW1|VIEW:WINDow2:TRACe:FVECtor[:STATe] :DISPlay:RHO:VIEW1|VIEW:WINDow2:TRACe:IQCHips :DISPlay:RHO:VIEW1|VIEW:WINDow2:TRACe:POLar :DISPlay:RHO:VIEW1|VIEW:WINDow2:TRACe:ROTQpi[:STATe] :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:RLEVel :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:RPOSition :DISPlay:RHO:VIEW2:WINDow2:TRACe:X[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow2:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO:VIEW2:WINDow2:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO:VIEW2:WINDow2:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO:VIEW2:WINDow2:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow2:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO:VIEW2:WINDow2:TRACe:Y[:SCALe]:RLEVel :DISPlay:RHO:VIEW2:WINDow2:TRACe:Y[:SCALe]:RPOSition :DISPlay:RHO:VIEW2:WINDow3:TRACe:X[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow3:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO:VIEW2:WINDow3:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO:VIEW2:WINDow3:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO:VIEW2:WINDow3:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow3:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO:VIEW2:WINDow3:TRACe:Y[:SCALe]:RLEVel Keysight N9083A & W9083A Measurement Guide...
  • Page 76 GSM/EDGE Format Parameter List Since most parameters are the same as those used in the original measurement, the SCPI commands in the original measurement can be used in this measurement by converting the measurement node. Keysight N9083A & W9083A Measurement Guide...
  • Page 77 Mod Scheme [:SENSe]:SYNC:HSRate:MODulation [:SENSe]:RADio:FORMat:GSM{1:3}:SYNC:HSRate:MODula tion Mod Scheme [:SENSe]:SYNC:HSRate:MODulation:AU [:SENSe]:RADio:FORMat:GSM{1:3}:SYNC:HSRate:MODula HSR Auto tion:AUTO Mod Scheme [:SENSe]:SYNC:NORMal:MODulation [:SENSe]: RADio:FORMat:GSM{1:3}:SYNC:NORMal:MODulation AQPSK SCPIR [:SENSe]:SYNC:NORMal:MODulation:AQ [:SENSe]:RADio:FORMat:GSM{1:3}:SYNC:NORMal:MODul PSk:ALPHa:SCPir ation:AQPSk:ALPHa:SCPir Mod Scheme [:SENSe]:SYNC:NORMal:MODulation:AU [:SENSe]:RADio:FORMat:GSM{1:3}:SYNC:NORMal:MODul Auto ation:AUTO AQPSK AutoDet [:SENSe]:SYNC:NORMal:MODulation:AU [:SENSe]:RADio:FORMat:GSM{1:3}:SYNC:NORMal:MODul TO:AQPSk ation:AUTO:AQPSk Keysight N9083A & W9083A Measurement Guide...
  • Page 78 SCPI Command not available in this measurement :CALCulate:EEVM:LIMit:BTS:EXTReme:EVMP95 :CALCulate:EEVM:LIMit:BTS:EXTReme:FERRor :CALCulate:EEVM:LIMit:BTS:EXTReme:IQOOffset :CALCulate:EEVM:LIMit:BTS:EXTReme:PEVM :CALCulate:EEVM:LIMit:BTS:EXTReme:PPERror :CALCulate:EEVM:LIMit:BTS:EXTReme:REVM :CALCulate:EEVM:LIMit:BTS:EXTReme:REVM:HSRate :CALCulate:EEVM:LIMit:BTS:EXTReme:REVM:NSRate :CALCulate:EEVM:LIMit:BTS:EXTReme:RPERror :CALCulate:EEVM:LIMit:BTS:NORMal:EVMP95 :CALCulate:EEVM:LIMit:BTS:NORMal:FERRor :CALCulate:EEVM:LIMit:BTS:NORMal:IQOOffset :CALCulate:EEVM:LIMit:BTS:NORMal:PEVM :CALCulate:EEVM:LIMit:BTS:NORMal:PPERror :CALCulate:EEVM:LIMit:BTS:NORMal:REVM :CALCulate:EEVM:LIMit:BTS:NORMal:REVM:HSRate :CALCulate:EEVM:LIMit:BTS:NORMal:REVM:NSRate :CALCulate:EEVM:LIMit:BTS:NORMal:RPERror :CALCulate:EEVM:LIMit:MBTS:EXTReme:FERRor :CALCulate:EEVM:LIMit:MBTS:NORMal:FERRor :CALCulate:EEVM:LIMit:MS:EXTReme:EVMP95 :CALCulate:EEVM:LIMit:MS:EXTReme:FERRor Keysight N9083A & W9083A Measurement Guide...
  • Page 79 MSR Measurement Concepts :CALCulate:EEVM:LIMit:MS:EXTReme:IQOOffset :CALCulate:EEVM:LIMit:MS:EXTReme:PEVM :CALCulate:EEVM:LIMit:MS:EXTReme:PPERror :CALCulate:EEVM:LIMit:MS:EXTReme:REVM :CALCulate:EEVM:LIMit:MS:EXTReme:REVM:HSRate :CALCulate:EEVM:LIMit:MS:EXTReme:REVM:NSRate :CALCulate:EEVM:LIMit:MS:EXTReme:RPERror :CALCulate:EEVM:LIMit:MS:NORMal:EVMP95 :CALCulate:EEVM:LIMit:MS:NORMal:FERRor :CALCulate:EEVM:LIMit:MS:NORMal:IQOOffset :CALCulate:EEVM:LIMit:MS:NORMal:PEVM :CALCulate:EEVM:LIMit:MS:NORMal:PPERror :CALCulate:EEVM:LIMit:MS:NORMal:REVM :CALCulate:EEVM:LIMit:MS:NORMal:REVM:HSRate :CALCulate:EEVM:LIMit:MS:NORMal:REVM:NSRate :CALCulate:EEVM:LIMit:MS:NORMal:RPERror :CALCulate:EEVM:LIMit:PBTS:EXTReme:FERRor :CALCulate:EEVM:LIMit:PBTS:NORMal:FERRor :CALCulate:EEVM:LIMit:TEST[:STATe] :CALCulate:EEVM:LIMit:TYPE :CALCulate:EEVM:MARKer{1:12}:AOFF/nquery/ :CALCulate:EEVM:MARKer{1:12}:COUPle[:STATe] :CALCulate:EEVM:MARKer{1:12}:FUNCtion:RESult?/qonly/ :CALCulate:EEVM:MARKer{1:12}:MAXimum/nquery/ :CALCulate:EEVM:MARKer{1:12}:MINimum/nquery/ :CALCulate:EEVM:MARKer{1:12}:MODE :CALCulate:EEVM:MARKer{1:12}:REFerence :CALCulate:EEVM:MARKer{1:12}:STATe :CALCulate:EEVM:MARKer{1:12}:TRACe :CALCulate:EEVM:MARKer{1:12}:X :CALCulate:EEVM:MARKer{1:12}:X:POSition :CALCulate:EEVM:MARKer{1:12}:Y?/qonly/ Keysight N9083A & W9083A Measurement Guide...
  • Page 80 MSR Measurement Concepts :DISPlay:EEVM:SDERotation[:STATe] :DISPlay:EEVM:SDOTs[:STATe] [:SENSe]:EEVM:SDOTs[:STATe] (BWCC) :DISPlay:EEVM:TEXT:TFUNit :DISPlay:EEVM:VIEW1|VIEW:NSELect :DISPlay:EEVM:VIEW1|VIEW[:SELect] :DISPlay:EEVM:VIEW1|VIEW:WINDow2:TRACe:POLar :DISPlay:EEVM:VIEW2:WINDow:TRACe:MAXHold[:STATe] :DISPlay:EEVM:VIEW2:WINDow:TRACe:MINHold[:STATe] :DISPlay:EEVM:VIEW2:WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:EEVM:VIEW2:WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:EEVM:VIEW2:WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:EEVM:VIEW2:WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:EEVM:VIEW2:WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:EEVM:VIEW2:WINDow:TRACe:Y[:SCALe]:PDIVision :DISPlay:EEVM:VIEW2:WINDow:TRACe:Y[:SCALe]:RLEVel :DISPlay:EEVM:VIEW2:WINDow:TRACe:Y[:SCALe]:RPOSition :DISPlay:EEVM:VIEW2:WINDow2:TRACe:X[:SCALe]:COUPle :DISPlay:EEVM:VIEW2:WINDow2:TRACe:X[:SCALe]:PDIVision :DISPlay:EEVM:VIEW2:WINDow2:TRACe:X[:SCALe]:RLEVel :DISPlay:EEVM:VIEW2:WINDow2:TRACe:X[:SCALe]:RPOSition :DISPlay:EEVM:VIEW2:WINDow2:TRACe:Y[:SCALe]:COUPle :DISPlay:EEVM:VIEW2:WINDow2:TRACe:Y[:SCALe]:PDIVision :DISPlay:EEVM:VIEW2:WINDow2:TRACe:Y[:SCALe]:RLEVel :DISPlay:EEVM:VIEW2:WINDow2:TRACe:Y[:SCALe]:RPOSition :DISPlay:EEVM:VIEW2:WINDow3:TRACe:X[:SCALe]:COUPle :DISPlay:EEVM:VIEW2:WINDow3:TRACe:X[:SCALe]:PDIVision :DISPlay:EEVM:VIEW2:WINDow3:TRACe:X[:SCALe]:RLEVel :DISPlay:EEVM:VIEW2:WINDow3:TRACe:X[:SCALe]:RPOSition :DISPlay:EEVM:VIEW2:WINDow3:TRACe:Y[:SCALe]:COUPle :DISPlay:EEVM:VIEW2:WINDow3:TRACe:Y[:SCALe]:PDIVision :DISPlay:EEVM:VIEW2:WINDow3:TRACe:Y[:SCALe]:RLEVel Keysight N9083A & W9083A Measurement Guide...
  • Page 81 The following SCPI commands in the cdma2000 Mod Accuracy are not available in this measurement. SCPI Command not available in this measurement :CALCulate:RHO:DTXBurst :CALCulate:RHO:LIMit:CDERror :CALCulate:RHO:LIMit:PEAK :CALCulate:RHO:LIMit:PHASe :CALCulate:RHO:LIMit:RHO :CALCulate:RHO:LIMit:RMS :CALCulate:RHO:LIMit:TIMing :CALCulate:RHO:MARKer{1:12}:AOFF/nquery/ :CALCulate:RHO:MARKer{1:12}:CHIP :CALCulate:RHO:MARKer{1:12}:COUPle[:STATe] :CALCulate:RHO:MARKer{1:12}:CPEak[:STATe] :CALCulate:RHO:MARKer{1:12}:FUNCtion:RESult?/qonly/ :CALCulate:RHO:MARKer{1:12}:MAXimum/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:HIGHer/nquery/ Keysight N9083A & W9083A Measurement Guide...
  • Page 82 MSR Measurement Concepts :CALCulate:RHO:MARKer{1:12}:MAXimum:LEFT/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:LOWer/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:NEXT/nquery/ :CALCulate:RHO:MARKer{1:12}:MAXimum:RIGHt/nquery/ :CALCulate:RHO:MARKer{1:12}:MINimum/nquery/ :CALCulate:RHO:MARKer{1:12}:MODE :CALCulate:RHO:MARKer{1:12}:PTPeak/nquery/ :CALCulate:RHO:MARKer{1:12}:REFerence :CALCulate:RHO:MARKer{1:12}:STATe :CALCulate:RHO:MARKer{1:12}:TRACe :CALCulate:RHO:MARKer{1:12}:X :CALCulate:RHO:MARKer{1:12}:X:POSition :CALCulate:RHO:MARKer{1:12}:Y?/qonly/ :DISPlay:RHO:ANNotation:TITLe:DATA :DISPlay:RHO:VIEW1|VIEW:NSELect :DISPlay:RHO:VIEW1|VIEW[:SELect] :DISPlay:RHO:VIEW1|VIEW:WINDow:TEXT:TFUNit :DISPlay:RHO:VIEW1|VIEW:WINDow:TRACe:COFFset :DISPlay:RHO:VIEW1|VIEW:WINDow:TRACe:FVECtor[:STATe] :DISPlay:RHO:VIEW1|VIEW:WINDow:TRACe:IQCHips :DISPlay:RHO:VIEW1|VIEW:WINDow:TRACe:POLar :DISPlay:RHO:VIEW1|VIEW:WINDow:TRACe:ROTQpi[:STATe] :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:RLEVel :DISPlay:RHO:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:RPOSition :DISPlay:RHO:VIEW2:WINDow2:TRACe:X[:SCALe]:COUPle :DISPlay:RHO:VIEW2:WINDow2:TRACe:X[:SCALe]:PDIVision Keysight N9083A & W9083A Measurement Guide...
  • Page 83 [:SENSe]:RADio:FORMat:EVDO{1:3}:PLSubtype The following SCPI commands in the 1xEV-DO Mod Accuracy measurement are converted for this measurement as follows: SCPI Command in Mod Accuracy SCPI Command in this measurement [:SENSe]:RHO[:BTS]:AVERage:COUNt [:SENSe]:CEVM:EVDO:AVERage:COUNt [:SENSe]:RHO:MS:AVERage:COUNt [:SENSe]:RHO[:BTS]:AVERage[:STATe] [:SENSe]:CEVM:EVDO:AVERage[:STATe] [:SENSe]:RHO:MS:AVERage[:STATe] Keysight N9083A & W9083A Measurement Guide...
  • Page 84 SCPI Command not available in this measurement :CALCulate:RHO[:BTS]:LIMit:DATA[:ACTive]:LOWer :CALCulate:RHO[:BTS]:LIMit:DATA[:ACTive][:UPPer] :CALCulate:RHO[:BTS]:LIMit:FREQuency :CALCulate:RHO[:BTS]:LIMit:MAC:INACtive[:UPPer] :CALCulate:RHO[:BTS]:LIMit:PEAK :CALCulate:RHO[:BTS]:LIMit:PHASe :CALCulate:RHO[:BTS]:LIMit:POFFset :CALCulate:RHO[:BTS]:LIMit:PRESet :CALCulate:RHO[:BTS]:LIMit:RHO:ALL :CALCulate:RHO[:BTS]:LIMit:RHO:DATA :CALCulate:RHO[:BTS]:LIMit:RHO:MAC :CALCulate:RHO[:BTS]:LIMit:RHO:PILot :CALCulate:RHO[:BTS]:LIMit:RHO:PREamble :CALCulate:RHO[:BTS]:LIMit:RMS :CALCulate:RHO[:BTS]:LIMit:TIMing :CALCulate:RHO[:BTS]:MARKer{1:12}:AOFF/nquery/ :CALCulate:RHO[:BTS]:MARKer{1:12}:CHIP :CALCulate:RHO[:BTS]:MARKer{1:12}:COUPle[:STATe] :CALCulate:RHO[:BTS]:MARKer{1:12}:MAXimum/nquery/ :CALCulate:RHO[:BTS]:MARKer{1:12}:MAXimum:LEFT/nquery/ :CALCulate:RHO[:BTS]:MARKer{1:12}:MAXimum:NEXT/nquery/ :CALCulate:RHO[:BTS]:MARKer{1:12}:MAXimum:RIGHt/nquery/ :CALCulate:RHO[:BTS]:MARKer{1:12}:MINimum/nquery/ :CALCulate:RHO[:BTS]:MARKer{1:12}:MODE :CALCulate:RHO[:BTS]:MARKer{1:12}:PTPeak/nquery/ Keysight N9083A & W9083A Measurement Guide...
  • Page 85 MSR Measurement Concepts :CALCulate:RHO[:BTS]:MARKer{1:12}:REFerence :CALCulate:RHO[:BTS]:MARKer{1:12}:STATe :CALCulate:RHO[:BTS]:MARKer{1:12}:TRACe :CALCulate:RHO[:BTS]:MARKer{1:12}:X :CALCulate:RHO[:BTS]:MARKer{1:12}:X:POSition :CALCulate:RHO[:BTS]:MARKer{1:12}:Y?/qonly/ :CALCulate:RHO[:BTS]:WCODe:ORDer :CALCulate:RHO[:BTS]:IQ:COMBined[:STATe] :DISPlay:RHO[:BTS]:ANNotation:TITLe:DATA :DISPlay:RHO[:BTS]:CDEScramble[:STATe] :DISPlay:RHO[:BTS]:CHANnel:TYPE :DISPlay:RHO[:BTS]:FVECtor[:STATe] :DISPlay:RHO[:BTS]:INTerpolate :DISPlay:RHO[:BTS]:IQCHips :DISPlay:RHO[:BTS]:IQPType :DISPlay:RHO[:BTS]:OFFSet :DISPlay:RHO[:BTS]:ROTQpi[:STATe] :DISPlay:RHO[:BTS]:VIEW:NSELect :DISPlay:RHO[:BTS]:VIEW[:SELect] :DISPlay:RHO[:BTS]:VIEW5:WINDow1|WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW5:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW5:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW5:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW5:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW5:WINDow1|WINDow:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW5:WINDow1|WINDow:TRACe:Y[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW5:WINDow1|WINDow:TRACe:Y[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW5:WINDow2:TRACe:X[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW5:WINDow2:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW5:WINDow2:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW5:WINDow2:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW5:WINDow2:TRACe:Y[:SCALe]:COUPle Keysight N9083A & W9083A Measurement Guide...
  • Page 86 MSR Measurement Concepts :DISPlay:RHO[:BTS]:VIEW5:WINDow2:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW5:WINDow2:TRACe:Y[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW5:WINDow2:TRACe:Y[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW5:WINDow3:TRACe:X[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW5:WINDow3:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW5:WINDow3:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW5:WINDow3:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW5:WINDow3:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW5:WINDow3:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW5:WINDow3:TRACe:Y[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW5:WINDow3:TRACe:Y[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW6:WINDow1|WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW6:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW6:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW6:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW6:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW6:WINDow1|WINDow:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW6:WINDow1|WINDow:TRACe:Y[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW6:WINDow1|WINDow:TRACe:Y[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW6:WINDow2:TRACe:X[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW6:WINDow2:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW6:WINDow2:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW6:WINDow2:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW6:WINDow2:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW6:WINDow2:TRACe:Y[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW6:WINDow2:TRACe:Y[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW6:WINDow2:TRACe:Y[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW7:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO[:BTS]:VIEW7:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO[:BTS]:VIEW7:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO[:BTS]:VIEW7:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:RHO[:BTS]:VIEW7:WINDow1|WINDow:TRACe:Y[:SCALe]:PDIVision Keysight N9083A & W9083A Measurement Guide...
  • Page 87 MSR Measurement Concepts :DISPlay:RHO[:BTS]:VIEW7:WINDow1|WINDow:TRACe:Y[:SCALe]:RLEVel [:SENSe]:RHO[:BTS]:AVERage:TCONtrol [:SENSe]:RHO[:BTS]:TRIGger:SOURce [:SENSe]:RHO:SWEep:POINts :CALCulate:RHO:MS:IQ:COMBined[:STATe] :CALCulate:RHO:MS:LIMit:ACDPower[:SUB0] :CALCulate:RHO:MS:LIMit:ACDPower:SUB2 :CALCulate:RHO:MS:LIMit:ACK:GAIN[:SUB0] :CALCulate:RHO:MS:LIMit:ACK:GAIN:SUB2 :CALCulate:RHO:MS:LIMit:AUXPilot:GAIN:SUB2 :CALCulate:RHO:MS:LIMit:CDERror[:SUB0] :CALCulate:RHO:MS:LIMit:CDERror:SUB2 :CALCulate:RHO:MS:LIMit:DATA:GAIN[:SUB0] :CALCulate:RHO:MS:LIMit:DRC:GAIN[:SUB0] :CALCulate:RHO:MS:LIMit:DRC:GAIN:SUB2 :CALCulate:RHO:MS:LIMit:DSC:GAIN:SUB2 :CALCulate:RHO:MS:LIMit:FERRor[:SUB0] :CALCulate:RHO:MS:LIMit:FERRor:SUB2 :CALCulate:RHO:MS:LIMit:ICDPower[:SUB0] :CALCulate:RHO:MS:LIMit:ICDPower:SUB2 :CALCulate:RHO:MS:LIMit:PEAK[:SUB0] :CALCulate:RHO:MS:LIMit:PEAK:SUB2 :CALCulate:RHO:MS:LIMit:POFFset[:SUB0] :CALCulate:RHO:MS:LIMit:POFFset:SUB2 :CALCulate:RHO:MS:LIMit:RHO[:SUB0] :CALCulate:RHO:MS:LIMit:RHO:SUB2 :CALCulate:RHO:MS:LIMit:RMS[:SUB0] :CALCulate:RHO:MS:LIMit:RMS:SUB2 :CALCulate:RHO:MS:LIMit:RRI:GAIN:SUB2 :CALCulate:RHO:MS:LIMit:RRI[:SUB0] :CALCulate:RHO:MS:LIMit:T2P:TOTal:GAIN:SUB2 :CALCulate:RHO:MS:MARKer{1:12}:AOFF Keysight N9083A & W9083A Measurement Guide...
  • Page 88 MSR Measurement Concepts :CALCulate:RHO:MS:MARKer{1:12}:CHIP :CALCulate:RHO:MS:MARKer{1:12}:COUPle[:STATe] :CALCulate:RHO:MS:MARKer{1:12}:MAXimum :CALCulate:RHO:MS:MARKer{1:12}:MAXimum:LEFT :CALCulate:RHO:MS:MARKer{1:12}:MAXimum:NEXT :CALCulate:RHO:MS:MARKer{1:12}:MAXimum:RIGHt :CALCulate:RHO:MS:MARKer{1:12}:MINimum :CALCulate:RHO:MS:MARKer{1:12}:MODE :CALCulate:RHO:MS:MARKer{1:12}:PTPeak :CALCulate:RHO:MS:MARKer{1:12}:REFerence :CALCulate:RHO:MS:MARKer{1:12}:STATe :CALCulate:RHO:MS:MARKer{1:12}:TRACe :CALCulate:RHO:MS:MARKer{1:12}:X :CALCulate:RHO:MS:MARKer{1:12}:X:POSition :CALCulate:RHO:MS:MARKer{1:12}:Y?/qonly/ :CALCulate:RHO:MS:WCODe:ORDer :DISPlay:RHO:MS:ANNotation:TITLe:DATA :DISPlay:RHO:MS:FVECtor[:STATe] :DISPlay:RHO:MS:INTerpolate :DISPlay:RHO:MS:IQCHips :DISPlay:RHO:MS:IQPType :DISPlay:RHO:MS:MARKer:CONSolidated :DISPlay:RHO:MS:OFFSet :DISPlay:RHO:MS:PointPerChip :DISPlay:RHO:MS:ROTQpi[:STATe] :DISPlay:RHO:MS:VIEW1|VIEW:NSELect :DISPlay:RHO:MS:VIEW1|VIEW[:SELect] :DISPlay:RHO:MS:VIEW3:WINDow1|WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:RHO:MS:VIEW3:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:RHO:MS:VIEW3:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:RHO:MS:VIEW3:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:RHO:MS:VIEW3:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle Keysight N9083A & W9083A Measurement Guide...
  • Page 89 TD-SCDMA Format Parameter List Since most parameters are the same as those used in the original measurement, the SCPI commands in the original measurement can be used in this measurement by converting the measurement node. Keysight N9083A & W9083A Measurement Guide...
  • Page 90 Mod Scheme [:SENSe]:TDEMod:MODScheme:AUTO [:SENSe]:RADio:FORMat:TDSCdma&%1:3&~:TDEMod:MO DScheme:AUTO Midamble Shift [:SENSe]:TDEMod:MSHift [:SENSe]:RADio:FORMat:TDSCdma&%1:3&~:TDEMod:MS Hift Max User for [:SENSe]:TDEMod:MXUSer:TS0 [:SENSe]:RADio:FORMat:TDSCdma&%1:3&~:TDEMod:MX USer:TS0 Max User for [:SENSe]:TDEMod:MXUSer:TS1|TS [:SENSe]:RADio:FORMat:TDSCdma&%1:3&~:TDEMod:MX USer:TS1|TS Max User for [:SENSe]:TDEMod:MXUSer:TS2 [:SENSe]:RADio:FORMat:TDSCdma&%1:3&~:TDEMod:MX USer:TS2 Max User for [:SENSe]:TDEMod:MXUSer:TS3 [:SENSe]:RADio:FORMat:TDSCdma&%1:3&~:TDEMod:MX USer:TS3 Keysight N9083A & W9083A Measurement Guide...
  • Page 91 [:SENSe]:TDEMod:UPTS [:SENSe]:RADio:FORMat:TDSCdma&%1:3&~:TDEMod:UPT The following SCPI commands in the TD-SCDMA Mod Accuracy measurement are converted for this measurement as follows: SCPI Command in TD-SCDMA Mod SCPI Command in this measurement Accuracy [:SENSe]:EEVM:AVERage:COUNt [:SENSe]:CEVM:TDSCdma:AVERage:COUNt [:SENSe]:EEVM:AVERage[:STATe] [:SENSe]:CEVM:TDSCdma:AVERage[:STATe] Keysight N9083A & W9083A Measurement Guide...
  • Page 92 SCPI Command not available in this measurement :CALCulate:EVM:LIMit&%1:2&~:FERRor :CALCulate:EVM:LIMit&%1:2&~:PCDE :CALCulate:EVM:LIMit&%1:2&~:PEAK :CALCulate:EVM:LIMit&%1:2&~:RHO :CALCulate:EVM:LIMit&%1:2&~:RMS :CALCulate:EVM:MARKer&%1:12&~:AOFF/nquery/ :CALCulate:EVM:MARKer&%1:12&~:CHIP :CALCulate:EVM:MARKer&%1:12&~:COUPle[:STATe] :CALCulate:EVM:MARKer&%1:12&~:CPEak[:STATe] :CALCulate:EVM:MARKer&%1:12&~:FUNCtion:RESult?/qonly/ :CALCulate:EVM:MARKer&%1:12&~:MAXimum/nquery/ :CALCulate:EVM:MARKer&%1:12&~:MAXimum:HIGHer/nquery/ :CALCulate:EVM:MARKer&%1:12&~:MAXimum:LEFT/nquery/ :CALCulate:EVM:MARKer&%1:12&~:MAXimum:LOWer/nquery/ :CALCulate:EVM:MARKer&%1:12&~:MAXimum:NEXT/nquery/ :CALCulate:EVM:MARKer&%1:12&~:MAXimum:RIGHt/nquery/ :CALCulate:EVM:MARKer&%1:12&~:MINimum/nquery/ :CALCulate:EVM:MARKer&%1:12&~:MODE :CALCulate:EVM:MARKer&%1:12&~:PTPeak/nquery/ :CALCulate:EVM:MARKer&%1:12&~:REFerence :CALCulate:EVM:MARKer&%1:12&~:STATe :CALCulate:EVM:MARKer&%1:12&~:TRACe :CALCulate:EVM:MARKer&%1:12&~:X :CALCulate:EVM:MARKer&%1:12&~:X:POSition :CALCulate:EVM:MARKer&%1:12&~:Y?/qonly/ :DISPlay:EVM:ANNotation:TITLe:DATA :DISPlay:EVM:FVECtor[:STATe] :DISPlay:EVM:INTerpolate[:STATe] Keysight N9083A & W9083A Measurement Guide...
  • Page 93 MSR Measurement Concepts :DISPlay:EVM:IQPoints :DISPlay:EVM:IQPoints:OFFSet :DISPlay:EVM:IQPType :DISPlay:EVM:ROTation[:STATe] :DISPlay:EVM:VIEW1|VIEW:NSELect :DISPlay:EVM:VIEW1|VIEW[:SELect] :DISPlay:EVM:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:EVM:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:EVM:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:EVM:VIEW2:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:EVM:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:EVM:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:PDIVision :DISPlay:EVM:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:RLEVel :DISPlay:EVM:VIEW2:WINDow1|WINDow:TRACe:Y[:SCALe]:RPOSition :DISPlay:EVM:VIEW2:WINDow2:TRACe:X[:SCALe]:COUPle :DISPlay:EVM:VIEW2:WINDow2:TRACe:X[:SCALe]:PDIVision :DISPlay:EVM:VIEW2:WINDow2:TRACe:X[:SCALe]:RLEVel :DISPlay:EVM:VIEW2:WINDow2:TRACe:X[:SCALe]:RPOSition :DISPlay:EVM:VIEW2:WINDow2:TRACe:Y[:SCALe]:COUPle :DISPlay:EVM:VIEW2:WINDow2:TRACe:Y[:SCALe]:PDIVision :DISPlay:EVM:VIEW2:WINDow2:TRACe:Y[:SCALe]:RLEVel :DISPlay:EVM:VIEW2:WINDow2:TRACe:Y[:SCALe]:RPOSition :DISPlay:EVM:VIEW2:WINDow3:TRACe:X[:SCALe]:COUPle :DISPlay:EVM:VIEW2:WINDow3:TRACe:X[:SCALe]:PDIVision :DISPlay:EVM:VIEW2:WINDow3:TRACe:X[:SCALe]:RLEVel :DISPlay:EVM:VIEW2:WINDow3:TRACe:X[:SCALe]:RPOSition :DISPlay:EVM:VIEW2:WINDow3:TRACe:Y[:SCALe]:COUPle :DISPlay:EVM:VIEW2:WINDow3:TRACe:Y[:SCALe]:PDIVision :DISPlay:EVM:VIEW2:WINDow3:TRACe:Y[:SCALe]:RLEVel :DISPlay:EVM:VIEW2:WINDow3:TRACe:Y[:SCALe]:RPOSition :DISPlay:EVM:VIEW3:WINDow1|WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:EVM:VIEW3:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision Keysight N9083A & W9083A Measurement Guide...
  • Page 94 Concepts MSR Measurement Concepts :DISPlay:EVM:VIEW3:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:EVM:VIEW3:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:EVM:VIEW3:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:EVM:VIEW3:WINDow1|WINDow:TRACe:Y[:SCALe]:PDIVision :DISPlay:EVM:VIEW3:WINDow1|WINDow:TRACe:Y[:SCALe]:RLEVel :DISPlay:EVM:VIEW3:WINDow1|WINDow:TRACe:Y[:SCALe]:RPOSition :DISPlay:EVM:VIEW4:WINDow1|WINDow:TRACe:X[:SCALe]:COUPle :DISPlay:EVM:VIEW4:WINDow1|WINDow:TRACe:X[:SCALe]:PDIVision :DISPlay:EVM:VIEW4:WINDow1|WINDow:TRACe:X[:SCALe]:RLEVel :DISPlay:EVM:VIEW4:WINDow1|WINDow:TRACe:X[:SCALe]:RPOSition :DISPlay:EVM:VIEW4:WINDow1|WINDow:TRACe:Y[:SCALe]:COUPle :DISPlay:EVM:VIEW4:WINDow1|WINDow:TRACe:Y[:SCALe]:PDIVision :DISPlay:EVM:VIEW4:WINDow1|WINDow:TRACe:Y[:SCALe]:RLEVel :DISPlay:EVM:VIEW4:WINDow1|WINDow:TRACe:Y[:SCALe]:RPOSition [:SENSe]:EVM:AVERage:TCONtrol Keysight N9083A & W9083A Measurement Guide...
  • Page 95: Instrument Updates At Www.keysight.com

    Concepts Instrument Updates at www.keysight.com Instrument Updates at www.keysight.com These web locations can be used to access the latest information about the instrument, including the latest firmware version. http://www.keysight.com/find/pxa http://www.keysight.com/find/mxa http://www.keysight.com/find/exa http://www.keysight.com/find/cxa Keysight N9083A & W9083A Measurement Guide...
  • Page 96 This information is subject to change without notice. © Keysight Technologies 2008-2015 Edition 1, June 2015 N9083-90002 www.keysight.com...