Chapter 8
Manage Alarms
DLP-G130 Discontinue Alarm Suppression
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
If multiple CTC sessions are open, discontinuing suppression in one session will discontinue
Caution
suppression in all other open sessions.
To discontinue alarm suppression for the entire node:
Step 1
a.
b.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the System object will be cleared
in all views.
To discontinue alarm suppression for individual cards:
Step 2
a.
b.
c.
d.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the slot object (for example,
SLOT-16) will be cleared in all views.
To discontinue alarm suppression for ports, click the Provisioning > Alarm Profiles > Alarm Behavior
Step 3
tabs.
Step 4
Uncheck the Suppress Alarms check box for the port(s) that you no longer want to suppress.
Step 5
Click Apply.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from
the window using the Synchronize button.) The AS-CMD alarm with the port object (for example,
FAC-16-1) will be cleared in all views.
Return to your originating procedure (NTP).
Step 6
September 2005
This task discontinues alarm suppression and reenables alarm reporting on
a port, card, or node.
None
DLP-G129 Suppress Alarm Reporting, page 8-29
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Provisioning or higher
In node view, click the Provisioning > Alarm Profiles > Alarm Behavior tab.
Uncheck the Suppress Alarms check box.
In node view, click the Provisioning > Alarm Profiles > Alarm Behavior tabs.
Locate the card that is suppressed in the slot list.
Uncheck the Suppress Alarms column check box for that slot.