AIC-I Interface
(wire wrapping)
Each AEP alarm input port has provisionable label and severity. The alarm inputs have optocoupler
isolation. They have one common 32-VDC output and a maximum of 2 mA per input. Each opto-metal
oxide semiconductor (MOS) alarm output can operate by definable alarm condition, a maximum open
circuit voltage of 60 VDC, and a maximum current of 100 mA. See the
Controls" section on page 23-12
Figure 15-31
September 2005
AEP Printed Circuit Board Assembly
Input Connector
shows the AEP block diagram.
AEP Block Diagram
TIA/EIA 485
Inventory data
(EEPROM)
Power Supply
shows the wire-wrapping connections on the shelf backplane used to connect to the AEP.
Output Connector
AEP/AIE
CPLD
for further information.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0

15.9 ONS 15454 ANSI Alarm Expansion Panel

In Alarm Relays