Chapter 5
Provision Transponder and Muxponder Cards
Table 5-20
MXP_2.5G_10G and MXP_2.5G_10E Card Line Threshold Settings (continued)
Parameter Description
FC
Failure count
UAS
Unavailable
seconds
Click Apply.
Step 4
Return to your originating procedure (NTP).
Step 5
DLP-G303 Provision the MXP_2.5G_10G and MXP_2.5G_10E Trunk Port Alarm
and TCA Thresholds
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, double-click the MXP_2.5G_10G or MXP_2.5G_10E card where you want to change the
Step 1
trunk port alarm and TCA settings.
Step 2
Click the Provisioning > Optics Thresholds tabs.
Step 3
Select a 15 Min or 1 Day PM interval radio button and then click Refresh.
Note
September 2005
DLP-G303 Provision the MXP_2.5G_10G and MXP_2.5G_10E Trunk Port Alarm and TCA Thresholds
ONS 15454 Options
Numeric. Threshold display options include:
Direction—Near End or Far End
Interval—15 Min (minutes) or 1 day
Types—Line or Section (near end only)
Choose an option in each category and click
Refresh.
Numeric. Threshold display options include:
Direction—Near End or Far End
Interval—15 Min (minutes) or 1 day
Types—Line or Section (near end only)
Choose an option in each category and click
Refresh.
This task changes the MXP_2.5G_10G and MXP_2.5G_10E trunk port
alarm and TCA thresholds.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Provisioning or higher
You must modify 15 Min and 1 Day independently. To do so, choose the appropriate radio button
and click Refresh.
ONS 15454 SDH Options
Numeric. Threshold display options include:
Direction—Near End or Far End
Interval—15 Min (minutes) or 1 day
Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh.
Numeric. Threshold display options include:
Direction—Near End or Far End
Interval—15 Min (minutes) or 1 day
Types—Multiplex Section or
Regeneration Section (near end only)
Choose an option in each category and click
Refresh.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0