DLP-G271 Verify the AD-xC-xx.x Output Common Power
DLP-G271 Verify the AD-xC-xx.x Output Common Power
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
Display the AD-xC-xx.x card in card view.
Step 2
Click the Provisioning > Optical Line > Parameters tabs.
Verify that the Output Com port Power value is greater than the default no-power value of –30 dBm.
Step 3
Return to your originating procedure (NTP).
Step 4
DLP-G272 Verify the AD-xB-xx.x Output Common Power
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Display the AD-xB-xx.x card in card view.
Step 1
Click the Provisioning > Optical Line > Parameters tabs.
Step 2
Verify that the Output Com port Power value is greater than the default no-power value of –28 dBm.
Step 3
Return to your originating procedure (NTP).
Step 4
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
4-48
This task verifies the output common power of the AD-xC-xx.x cards.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser
This task verifies the output common power of the AD-xB-xx.x cards.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser
Chapter 4
Perform Node Acceptance Tests
September 2005