Table 5-44 Mxp_Mr_2.5G And Mxpp_Mr_2.5G Muxponder Card Line Sonet Or Sdh Tab Settings - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

DLP-G238 Change OC-48/STM-16 Settings for MXP_MR_2.5G and MXPP_MR_2.5G Cards
Table 5-44
MXP_MR_2.5G and MXPP_MR_2.5G Muxponder Card Line SONET or SDH Tab Settings
Parameter
Description
Port #
(Display only) Port number.
Port Name
Provides the ability to assign the specified port a
name.
Admin State
Sets the port service state unless network
conditions prevent the change. For more
information about administrative states, see
Appendix C, "DWDM Administrative and
Service States."
Service State
Identifies the autonomously generated state that
gives the overall condition of the port. Service
states appear in the format: Primary
State-Primary State Qualifier, Secondary State.
For more information about service states, see
Appendix C, "DWDM Administrative and
Service States."
1
SF BER
Sets the signal fail bit error rate.
1
SD BER
Sets the signal degrade bit error rate.
AINS Soak
Sets the automatic in-service soak period.
Double-click the time and use the up and down
arrows to change settings.
Type
The optical transport type.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
5-72
Chapter 5
Provision Transponder and Muxponder Cards
Options
9 (trunk for MXP_MR_2.5G) or 9 and 10 (trunks for
MXPP_MR_2.5G)
User-defined. Name can be up to 32 alphanumeric/
special characters. Blank by default.
See the
"DLP-G104 Assign a Name to a Port" task on
page
7-10.
IS (ANSI) or Unlocked (ETSI)
IS,AINS (ANSI) or Unlocked,automaticInService
(ETSI)
OOS,DSBLD (ANSI) or Locked,disabled (ETSI)
OOS,MT (ANSI) or Locked,maintenance (ETSI)
IS-NR (ANSI) or Unlocked-enabled (ETSI)
OOS-AU,AINS (ANSI) or Unlocked-disabled,
automaticInService (ETSI)
OOS-MA,DSBLD (ANSI) or
Locked-enabled,disabled (ETSI)
OOS-MA,MT (ANSI) or
Locked-enabled,maintenance (ETSI)
1E-3
1E-4
1E-5
1E-5
1E-6
1E-7
1E-8
1E-9
Duration of valid input signal, in hh.mm format,
after which the card becomes in service (IS)
automatically
0 to 48 hours, 15-minute increments
SONET (ANSI)
SDH (ETSI)
September 2005

Advertisement

Table of Contents
loading

Table of Contents