Cisco ONS 15454 DWDM Installation And Operation Manual page 234

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

NTP-G32 Install the Transponder and Muxponder Cards
Step 2
Remove the TXP or MXP card from its packaging, then remove the protective clips from the backplane
connectors.
Open the card latches/ejectors.
Step 3
Step 4
Use the latches/ejectors to firmly slide the TXP or MXP card along the guide rails until the card plugs
into the receptacle at the back of the slot designated by the Cisco MetroPlanner shelf layout.
Note
Step 5
Verify that the card is inserted correctly and close the latches/ejectors on the card.
Note
The following LED activity will occur:
The red FAIL LED turns on for approximately 30 seconds. During this time, the ACT LED will cycle
through various states, and then extinguish.
The red FAIL LED blinks for approximately 45 seconds.
All LEDs blink once and turn off for approximately 10 seconds while the ACT and SF LEDs cycle
through various stages.
The ACT or ACT/STBY LED turns on. The SF LED might persist until all card ports connect to
their far-end counterparts and a signal is present.
Until a TXP or MXP is provisioned, the card is in the standby condition and the ACT/STBY LED
Note
remains amber in color.
If the card does not boot up properly, or the LED activity does not mirror
Step 6
When a physical card type does not match the type of card provisioned for that slot in CTC, the card
might not boot. If a TXP or MXP card does not boot, open CTC and ensure that the slot is not
provisioned for a different card type before assuming that the card is faulty.
If the red FAIL LED does not turn on, check the power.
If you insert a card into a slot provisioned for a different card, all LEDs turn off.
If the red FAIL LED is on continuously or the LEDs behave erratically, the card is not installed
properly. Remove the card and repeat Steps
If the TXP or MXP requires a Small Form-factor Pluggable (SFP or XFP) connector, complete one of
Step 7
the following tasks:
DLP-G63 Install an SFP or XFP, page
into the TXP or MXP.
DLP-G273 Preprovision an SFP or XFP Slot, page
not have the physical SFP or XFP and wish to preprovision the SFP or XFP slot. If you preprovision
a multirate SFP or XFP, complete the
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
3-44
If you install the wrong card in a slot, complete the
Cards" procedure on page
It is possible to close the latches and ejectors when the card is not completely plugged into the
backplane. Ensure that you cannot insert the card any further.
"NTP-G107 Remove and Replace DWDM
12-1.
3
to 5.
3-45—Complete this task to install the physical SFP or XFP
3-46—(Optional) Complete this task if you do
"DLP-G278 Provision the Optical Line Rate" task on page
Chapter 3
Turn Up a Node
Step
5, check the following:
5-6.
September 2005