Perform Node Acceptance Tests
Step 14
Complete the
east OPT-BST amplifier.
Disconnect the TXP or tunable laser from the east OPT-BST card.
Step 15
Step 16
Remove the loopback on the west OPT-BST created in
Step 17
Create a loopback on the east OPT-BST by connecting a patchcord from the LINE TX port to the LINE
RX port with a 10-dB bulk attenuator.
If you are using a tunable laser, follow the manufacturer's instructions to complete the following steps.
Step 18
If you are using a TXP_MR_2.5G card, continue with
Set the output power to a nominal value, such as –3 dBm.
a.
Set the tuner to the wavelength under test, then continue with
b.
If you are using a TXP_MR_2.5G card, complete the
Step 19
Acceptance Testing" task on page 4-4
Table 4-1 on page
Connect the tunable laser transmitter or the TXP_MR_2.5G card DWDM TX port to the LINE RX port
Step 20
of the west OPT-BST using a 10-dB bulk attenuator.
Failure to use proper attenuation might damage equipment.
Caution
Step 21
Wait 90 seconds, then in node view click the Alarms tab. Verify that the LOS alarms on the east
OPT-BST and OSCM cards have cleared. The clearing of the LOS alarms indicates that the OSC link is
active on the east side.
Note
If the alarms clear, continue with
Display the east OPT-BST card in card view.
a.
b.
Click the Provisioning > Optical Line > Optics Thresholds tabs.
c.
Under Types, click Alarms, then click Refresh.
d.
Locate the Port 2 Power Failure Low parameter. Double-click the table cell and change the value to
–30 dBm.
e.
Locate the Port 4 Power Failure Low parameter. Double-click the table cell and change the value to
–40 dBm.
Click Apply, and then Yes.
f.
Wait 90 seconds, then in node view click the Alarms tab. Verify that the LOS alarms on the east
g.
OPT-BST card has cleared. If so, continue with
OPT-BST.
Create a loopback on the OSCM card by connecting a patch cable from the OSC TX port to the OSC
h.
RX port using a 10-dB bulk attenuator.
Wait 90 seconds, then in node view click the Alarms tab. Verify that the LOS alarms on the east
i.
OSCM card has cleared. If so, replace the OPT-BST card. If not, replace the OSCM card. See
the"NTP-G30 Install the DWDM Cards" procedure on page
September 2005
"DLP-G79 Verify the OPT-BST Amplifier Laser and Power" task on page 4-40
4-4, if needed.
An SDCC Termination Failure alarm will continue to appear due to the OSC signal loopback.
An LOS-O alarm appears on the west OPT-BST card, and an LOS alarm appears on the west
OCSM card.
NTP-G45 Perform the Line Amplifier Node with OSCM Cards Acceptance Test
Step
Step
"DLP-G268 Provision TXP_MR_2.5G Cards for
for the TXP containing the wavelength you will test. Refer to
Step
22. If not, perform the following steps:
Step
22. If not, disconnect the OSCM card from the
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
6.
19.
Step
20.
3-39.
for the
4-25

Advertisement

Table of Contents
loading

Table of Contents