NTP-G66 View Alarm-Affected Circuits
Step 5
To remove the transient messages from the History window, click Delete Cleared Alarms. Transient
messages are single messages, not raise-and-clear pairs (that is, they do not have companion messages
stating that they are cleared).
Stop. You have completed this procedure.
NTP-G66 View Alarm-Affected Circuits
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
Step
Step 2
In network, node, or card view, click the Alarms tab or Conditions tab and then right-click anywhere
in the row of an active alarm or condition.
Note
The Select Affected Circuit option appears on the shortcut menu.
Left-click or right-click Select Affected Circuits.
Step 3
The Circuits window appears with the affected OCHNC highlighted.
Stop. You have completed this procedure.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
8-14
Use this procedure to view all optical channel network connections
(OCHNCs) and ONS 15454 circuits, if any, that are affected by an alarm
or condition.
None
NTP-G64 View Alarms, History, Events, and Conditions, page 8-6
As needed
Onsite or remote
Retrieve or higher
"DLP-G46 Log into CTC" task on page
2.
The node view is the default, but you can also navigate to the Alarms tab in the network view or
card view to perform Step 2.
Chapter 8
2-25. If you are already logged in, continue with
Manage Alarms
September 2005