Chapter 4
Perform Node Acceptance Tests
Step 13
Complete the
OSC-CSM card installed on the west side.
Return to your originating procedure (NTP).
Step 14
DLP-G87 Verify the AD-xB-xx.x Output Express Power
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
Display the AD-xB-xx.x card in card view.
Step 2
Click the Provisioning > Optical Line > Parameters tabs.
Step 3
Change the Output Express port Admin State to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Click Apply.
Step 4
Verify that the Output Express port Power value is greater than the default no-power value of –28 dBm.
Step 5
Return to your originating procedure (NTP).
DLP-G88 Verify the AD-xC-xx.x Output Express Power
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Display the AD-xC-xx.x card in card view.
Step 1
Click the Provisioning > Optical Line > Parameters tabs.
Step 2
Change the Output Express port Admin State to OOS,MT (ANSI) or Locked,maintenance (ETSI).
Step 3
Click Apply.
Verify that the Output Express port Power value is greater than the default no-power value of –30 dBm.
Step 4
Return to your originating procedure (NTP).
Step 5
September 2005
"DLP-G83 Verify the OSC-CSM Power on OADM Nodes" task on page 4-43
This task verifies the output express power of AD-xB-xx.x cards.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser
This task verifies the output express power of the AD-xC-xx.x cards.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser
DLP-G87 Verify the AD-xB-xx.x Output Express Power
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
for the
4-47