Dlp- G96 Set Up Internal Timing - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 6
Turn Up Network
DLP-G96 Set Up Internal Timing
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
Internal timing is Stratum 3 and is not intended for permanent use. All ONS 15454 SONET or SDH
nodes should be timed to a Stratum 2 or better primary reference source. Internal timing is appropriate
for DWDM nodes.
In node view, click the Provisioning > Timing > General tabs.
Step 1
In the General Timing area, enter the following:
Step 2
In the Reference Lists area, enter the following information:
Step 3
Step 4
Click Apply.
Click the BITS Facilities tab.
Step 5
In the BITS Facilities area, change the BITS In State and BITS Out State to OOS for BITS 1 and BITS 2.
Step 6
Disregard the other BITS Facilities settings; they are not relevant to internal timing.
Step 7
Click Apply.
Return to your originating procedure (NTP).
Step 8
September 2005
This task sets up internal timing (Stratum 3) for an ONS 15454.
None
DLP-G46 Log into CTC, page 2-25
As needed (use only if a BITS source is not available)
Onsite or remote
Provisioning or higher
Timing Mode—Set to External.
SSM Message Set—Set to Generation 1.
Quality of RES—Does not apply to internal timing.
Revertive—Does not apply to internal timing.
Revertive Time—Does not apply to internal timing.
NE Reference
Ref 1—Set to Internal Clock.
Ref 2—Set to Internal Clock.
Ref 3—Set to Internal Clock.
BITS-1 Out/BITS-2 Out—Set to None.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
DLP-G96 Set Up Internal Timing
6-7

Advertisement

Table of Contents
loading

Table of Contents