Table 5-25 Mxp_2.5G_10G And Mxp_2.5G_10E Muxponder Card Line Otn Settings; Table 5-26 Mxp_2.5G_10G And Mxp_2.5G_10E Muxponder Card Itu-T G.709 Threshold Settings - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 5
Provision Transponder and Muxponder Cards
Table 5-25
Parameter
Port #
G.709 OTN
FEC
SF BER
SD BER
Asynch/Synch
Mapping
Table 5-26
Table 5-26
Parameter
Port
ES
SES
UAS
September 2005
DLP-G228 Change Line OTN Settings for MXP_2.5G_10G and MXP_2.5G_10E Cards
MXP_2.5G_10G and MXP_2.5G_10E Muxponder Card Line OTN Settings
Description
(Display only) Displays the port number. 5
Sets the OTN lines according to
ITU-T G.709.
Sets the OTN line FEC mode. FEC mode
can be Disabled or Enabled. Enhanced
FEC mode can be enabled (to provide
greater range and lower bit error rate).
E-FEC applies only to the
MXP_2.5G_10E card.
Sets the signal fail bit error rate.
Sets the signal degrade bit error rate.
(MXP_2.5G_10E only) The
MXP_2.5G_10E can perform standard
ODU multiplexing according to
ITU-T G.709. The card uses this to
aggregate the four OC-48 client signals.
describes the values on the Provisioning > OTN > OTN G.709 Thresholds tab.
MXP_2.5G_10G and MXP_2.5G_10E Muxponder Card ITU-T G.709 Threshold Settings
Description
(Display only) Port number
Errored seconds
Severely errored seconds. Two types of
thresholds can be asserted. Selecting the
SM (OTUk) radio button selects FEC,
overhead management, and PM using
OTUk. Selecting the PM radio button
selects path PM using ODUk.
Unavailable seconds
Options
Enabled
Disabled
Enabled—(MXP_2.5G_10G only)
FEC is on
Disabled—FEC is off
Standard—(MXP_2.5G_10E only)
FEC is on
Enhanced—(MXP_2.5G_10E only)
Enhanced FEC is on
1E-5
1E-5
1E-6
1E-7
1E-8
1E-9
ODU Multiplex
Options
5
Numeric. Can be set for Near End or Far
End, for 15-minute or one-day intervals,
or for SM (OTUk) or PM (ODUk). Select
a bullet and click Refresh.
Numeric. Can be set for Near End or Far
End, for 15-minute or one-day intervals,
or for SM (OTUk) or PM (ODUk). Select
a bullet and click Refresh.
Numeric. Can be set for Near End or Far
End, for 15-minute or one-day intervals,
or for SM (OTUk) or PM (ODUk). Select
a bullet and click Refresh.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
5-45

Advertisement

Table of Contents
loading

Table of Contents