Dlp- G55 Create A New User On Multiple Nodes - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 3
Turn Up a Node
DLP-G55 Create a New User on Multiple Nodes
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
All nodes where you want to add users must be accessible in network view.
Note
From the View menu, choose Go to Network View.
Step 1
Step 2
Click the Provisioning > Security > Users tabs.
Step 3
In the Users window, click Create.
In the Create User dialog box, enter the following:
Step 4
In the Select Applicable Nodes area, deselect any nodes where you do not want to add the user (all
Step 5
network nodes are selected by default).
Step 6
Click OK.
In the User Creation Results dialog box, verify that the user was added to all the nodes chosen in
Step 7
If not, click OK and repeat Steps
with the next step.
Return to your originating procedure (NTP).
Step 8
September 2005
This task adds a new user to multiple ONS 15454 nodes.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Superuser
Name—Type the user name. The name must be a minimum of six and a maximum of
20 alphanumeric (a-z, A-Z, 0-9) characters. For TL1 compatibility, the user name must
6 to 10 characters.
Password—Type the user password. The password must be a minimum of six and a maximum of
20 alphanumeric (a-z, A-Z, 0-9) and special (+, #, %) characters, where at least two characters are
non alphabetic and at least one character is a special character. For TL1 compatibility, the password
must be 6 to 10 characters. The password must not contain the user name.
Confirm Password—Type the password again to confirm it.
Security Level—Choose a security level for the user: RETRIEVE, MAINTENANCE,
PROVISIONING, or SUPERUSER. Refer to the
page 20-1
for information about the capabilities provided with each level.
Each security level has a different idle time. The idle time is the length of time that CTC can
Note
remain idle before it locks up and the password must be reentered. The defaults are: Retrieve
user = unlimited, Maintenance user = 60 minutes, Provisioning user = 30 minutes, and
Superuser = 15 minutes. To change the idle times, refer to the
Change Security" procedure on page
"20.1 User IDs and Security Levels" section on
10-45.
2
through 6. If the user was added to all nodes, click OK and continue
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
DLP-G55 Create a New User on Multiple Nodes
"NTP-G88 Modify Users and
Step
5.
3-7