DLP-G209 Change Optical Line Threshold Settings for Multiplexer and Demultiplexer Cards
DLP-G209 Change Optical Line Threshold Settings for Multiplexer and
Demultiplexer Cards
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, double-click the multiplexer or demultiplexer card where you want to change the optical
Step 1
line threshold settings.
Step 2
Click the Provisioning > Optical Line > Optics Thresholds tabs.
Under Types, choose the type of threshold you want to change, either Warning or Alarm.
Step 3
Click Refresh.
Step 4
Modify any of the warning or alarm threshold settings.
Step 5
for warnings. The provisionable parameters are listed in the options column in the table.
Table 11-15
Parameter
Port
opwrMin
(dBm)
opwrMax
(dBm)
Warning thresholds are not monitored by CTC. They must be user-provisioned and monitored through
Caution
custom alarm profiles.
Table 11-16
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
11-26
This task changes the optical line threshold settings for 32MUX-O,
32DMX-O, 32DMX, and 4MD-xx.x multiplexer and demultiplexer cards.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Provisioning or higher
Multiplexer and Demultiplexer Card Amplifier Line Warning Threshold Settings
Description
(Display only) Displays the port number. —
Sets the low power warning level.
Sets the high power warning level.
shows the amplifier line thresholds for alarms.
Chapter 11
Change DWDM Card Settings
Table 11-15
shows the amplifier line thresholds
Options
Numeric. Can be set for 15-minute or
one-day intervals. The default is
–50 dBm. Double-click the parameter,
enter a value, and press Enter.
Numeric. Can be set for 15-minute or
one-day intervals. The default is 30 dBm.
Double-click the parameter, enter a value,
and press Enter.