Ntp- G44 Perform The Anti-Ase Hub Node Acceptance Test - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

NTP-G44 Perform the Anti-ASE Hub Node Acceptance Test
Step 19
Click the Performance > Optics PM > Current Values tabs.
Under the Port 2 (Trunk) column, locate the RX Optical Power value. Verify that the value matches the
Step 20
power in
the cable connecting the TXP_MR_2.5G RX port to the west fiber patch panel DMX port for the tested
wavelength. See the
If the power values still do not match (+/– 2 dBm), contact your next level of support.
Repeat Steps
Step 21
Step 22
Display the west 32WSS in card view.
Step 23
Click the Maintenance tab.
Click the table cell under Operating Mode and choose Not Assigned from the drop-down list for all
Step 24
wavelengths.
Step 25
Click Apply, then click Yes to confirm.
Step 26
Remove the TXP or tunable laser from the west side patch panel.
Unplug the physical loopback fiber from the line TX and RX in the OPT-BST or OSC-CSM card.
Step 27
Return to your originating procedure (NTP).
Step 28
NTP-G44 Perform the Anti-ASE Hub Node Acceptance Test
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
acceptance test. If you are already logged in, continue with
From the View menu, choose Go to Network View.
Step 2
Click the Alarms tab.
Step 3
a.
b.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
4-20
Step
16, +/– 2 dBm. If the power values do not match (+/– 2 dBm), remove, clean, and replace
"NTP-G115 Clean Fiber Connectors" procedure on page 13-25
4
through
20
for the remaining wavelengths.
This procedure tests an anti-ASE hub node.
A tunable laser or eight TXP_MR_2.5G cards covering the 32 C-band
wavelengths (see
An optical power meter or optical spectrum analyzer
2 bulk attenuators (10 dB) with LC connectors
Chapter 3, "Turn Up a Node."
Required
Onsite
Superuser
"DLP-G46 Log into CTC" task on page 2-25
Verify that the alarm filter is not on. See the
as necessary.
Verify that no equipment (EQPT) alarms appear indicating equipment failure or other hardware
problems. If alarms appear, investigate and resolve them before continuing. Refer to the
Cisco ONS 15454 Troubleshooting Guide or the Cisco ONS 15454 SDH Troubleshooting Guide for
procedures.
Chapter 4
Table
4-1)
at the node where you want to perform the
Step
2.
"DLP-G128 Disable Alarm Filtering" task on page 8-28
Perform Node Acceptance Tests
and repeat this step.
September 2005