DLP-G208 Change Optical Line Settings for Multiplexer and Demultiplexer Cards
DLP-G208 Change Optical Line Settings for Multiplexer and Demultiplexer
Cards
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In node view, double-click the multiplexer or demultiplexer card where you want to change the optical
Step 1
line settings.
Step 2
Click the Provisioning > Optical Line > Parameters tabs.
Modify any of the settings described in
Step 3
followed by the SDH option. The provisionable parameters are listed in the options column in the table.
Table 11-14
Multiplexer and Demultiplexer Card Optical Line Settings
Parameter
Description
Port #
(Display only) Displays the port number.
Port Name
Provides the ability to assign the specified port a
name.
Admin State
Sets the port service state unless network
conditions prevent the change. For more
information about administrative states, see
Appendix C, "DWDM Administrative and Service
States."
Line Direction Provides the ability to associate a card with the line
direction. CTC automatically configures the line
direction during node setup. To change this setting,
you must change the Cisco MetroPlanner site plan
and import it to the node.
Service State
Identifies the autonomously generated state that
gives the overall condition of the port. Service
states appear in the format: Primary State-Primary
State Qualifier, Secondary State. For more
information about service states, see
"DWDM Administrative and Service States."
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
11-24
This task changes the optical line settings for 32MUX-O, 32DMX-O,
32DMX, and 4MD-xx.x multiplexer and demultiplexer cards.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Provisioning or higher
Table
11-14. In the Options column, the SONET option is
Options
Displays port number and TX or RX.
User-defined. Name can be up to 32 alphanumeric/
special characters. Blank by default. Double-click,
enter the name, and press Enter.
See the
page
7-10.
From the drop-down list, choose one of the following:
IS/Unlocked
IS,AINS/Unlocked,automaticInService
OOS,DSBLD/Locked,disabled
OOS,MT/Locked,maintenance
From the drop-down list, choose one of the following:
East to West
West to East
Display only
IS-NR/Unlocked-enabled
OOS-AU,AINS/Unlocked-disabled,
automaticInService
Appendix C,
OOS-MA,DSBLD/Locked-enabled,disabled
OOS-MA,MT/Locked-enabled,maintenance
Chapter 11
Change DWDM Card Settings
"DLP-G104 Assign a Name to a Port" task on
September 2005

Advertisement

Table of Contents
loading