DLP-G315 Install Fiber-Optic Cables From the 32WSS/32DMX and 32MUX-O/32DMX-O Cards to the Patch Panel
DLP-G315 Install Fiber-Optic Cables From the 32WSS/32DMX and
32MUX-O/32DMX-O Cards to the Patch Panel
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
For a ROADM or hub node, two patch panels will be used, one for the east side and one for the west.
Note
The east side 32WSS/32DMX card will connect to the east patch panel. The west side 32WSS/32DMX
card will connect to the west patch panel.
Choose either the east or west side of the shelf to cable the 32MUX-O and 32DMX-O cards (or the
Step 4
32WSS and 32DMX cards for an ROADM node).
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
3-74
This task describes how to route fiber-optic cables from 32MUX-O,
32WSS, 32DMX-O, and 32DMX cards in a terminal, hub, or ROADM
node to the patch panel.
The following node types require the following equipment. The cards and
patch panels should already be installed before you begin this procedure.
Terminal node:
One 32DMX-O card
One 32MUX-O card
One Patch panel
Eight MPO cables: fiber-optic cables, terminated on one end with one
multifiber push-on (MPO) connector and on the other end with eight
LC-type connectors
Hub node:
Two 32DMX-O cards
Two 32MUX-O cards
Two patch panels
Sixteen MPO cables: fiber-optic cables, terminated on one end with
one multifiber push-on (MPO) connector and on the other end with
eight LC-type connectors
ROADM node:
Two 32WSS cards
Two 32DMX cards
Two patch panels
Sixteen MPO cables: fiber-optic cables, terminated on one end with
one multifiber push-on (MPO) connector and on the other end with
eight LC-type connectors
NTP-G34 Install Fiber-Optic Cables on DWDM Cards and DCUs, page
3-48
As needed
Onsite
None