Perform Node Acceptance Tests
c.
d.
Step 6
Verify the west 4MD-xx.x (west-to-east):
a.
b.
c.
Step 7
Verify the east 4MD-xx.x (west-to-east):
a.
b.
c.
d.
Step 8
Return to your originating procedure (NTP).
DLP-G93 Verify Add and Drop Connections on an OADM Node with OSCM Cards
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
In this task, you will verify add and drop connections in the following order: east-to-west add and
Note
west-to-east drop, Steps
Based on the Cisco MetroPlanner site configuration file, tune the tunable laser or TXP_MR_2.5G card
Step 1
to a wavelength (belonging to the 100-GHz ITU-T grid) of the channel running on the first add path of
the first west AD-xC-xx.x or west 4MD-xx.x card on the east-to-west direction. Refer to the tunable laser
manufacturer's documentation or the
Testing" task on page
Connect the tunable laser transmitter or the TXP_MR_2.5G card DWDM TX port to the corresponding
Step 2
15xx.x RX port (on the card front panel) of the west AD-xC-xx.x or 4MD-xx.x card.
Step 3
Verify the west AD-xC-xx.x or 4MD-xx.x (east-to-west):
a.
September 2005
Change the Admin State of the BAND TX port to OOS,MT (ANSI) or Locked,maintenance
(ETSI) for the channel related to the wavelength selected on the tunable laser.
Verify that the BAND TX Power value is higher than the default no-power value of –30 dBm.
Display the west 4MD-xx.x card in card view.
Click the Provisioning > Optical Chn > Parameters tabs.
Verify that the Power value on the CHAN TX port is higher than the default no-power value of
–35 dBm.
Display the east 4MD-xx.x card in card view.
Click the Provisioning > Optical Chn > Parameters tabs.
Change the Admin State of the CHAN RX port to OOS,MT (ANSI) or Locked,maintenance
(ETSI) for the channel related to the wavelength selected on the tunable laser.
Verify that the Power value of the CHAN RX port reaches the provisioned setpoint (VOA Power
Ref).
This task verifies the add and drop channel connections for an OADM node
with OSCM cards installed.
A tunable laser or eight TXP_MR_2.5G cards covering the 32 C-band
wavelengths (see
DLP-G46 Log into CTC, page 2-25
As needed
Onsite
Superuser
1
through 15; west-to-east add and east-to-west drop, Steps
4-4.
Display the west AD-xC-xx.x or 4MD-xx.x card in card view.
DLP-G93 Verify Add and Drop Connections on an OADM Node with OSCM Cards
Table 4-1 on page
"DLP-G268 Provision TXP_MR_2.5G Cards for Acceptance
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
4-4)
16
through 17.
4-53