Table 11-8 Opt-Pre And Opt-Bst Card Optical Channel Warning Thresholds Settings - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

DLP-G205 Change Optical Line Threshold Settings for OPT-PRE and OPT-BST Amplifiers
Step 4
Click Apply. If the change affects traffic, a warning message displays. Click Yes to complete the
change.
Return to your originating procedure (NTP).
Step 5
DLP-G205 Change Optical Line Threshold Settings for OPT-PRE and OPT-BST
Amplifiers
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Warning thresholds are not monitored by CTC. They must be user-provisioned and monitored through
Caution
custom alarm profiles.
In node view, double-click the OPT-PRE or OPT-BST amplifier where you want to change the optical
Step 1
line threshold settings.
Click the Provisioning > Optical Line > Optics Thresholds tabs.
Step 2
Step 3
Under Types, choose the type of threshold you want to change, either Warning or Alarm.
Click Refresh.
Step 4
Modify any of the warning or alarm threshold settings.
Step 5
Table 11-9
column in the table.
Table 11-8
Parameter
Port
opwrMin
(dBm)
opwrMax
(dBm)
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
11-14
This task changes the optical line threshold settings for OPT-PRE and
OPT-BST amplifier cards.
None
DLP-G46 Log into CTC, page 2-25
As needed
Onsite or remote
Provisioning or higher
shows the thresholds for alarms. The provisionable parameters are listed in the options
OPT-PRE and OPT-BST Card Optical Channel Warning Thresholds Settings
Description
(Display only) Displays the port number. —
Sets the low power warning level.
Sets the high power warning level.
Chapter 11
Change DWDM Card Settings
Table 11-8
shows the thresholds for warnings.
Options
Numeric. Can be set for 15-minute or
one-day intervals. The default is
–50 dBm. Double-click, enter the name,
and press Enter.
Numeric. Can be set for 15-minute or
one-day intervals. The default is 30 dBm.
Double-click, enter the name, and press
Enter.
September 2005