DLP-G93 Verify Add and Drop Connections on an OADM Node with OSCM Cards
b.
Click the Provisioning > Optical Chn > Parameters tabs.
Change the Admin State of the CHAN RX port to OOS,MT (ANSI) or Locked,maintenance
c.
(ETSI) for the channel related to the wavelength chosen on the tunable laser.
d.
Verify that the Power value of the CHAN RX port reaches the provisioned setpoint (VOA Power
Ref).
Complete the
Step 4
west OPT-BST amplifier to verify that the added wavelength turns on the laser.
If the add connection uses a 4MD-xx.x card, continue with
Step 5
AD-xC-xx.x card, move to
Verify the RX band port on the west AD-xB-xx.x card:
Step 6
Display the west Ad-xB-xx.x card in card view.
a.
Click the Provisioning > Optical Band > Parameters tabs.
b.
Verify that the BAND RX Power value is higher than the default no-power values of –30 dBm
Step 7
Verify band TX port on the west AD-xB-xx.x (west-to-east):
Step 8
Display the west AD-xB-xx.x card in card view.
a.
b.
Click the Provisioning > Optical Band > Parameters tabs.
c.
Change the Admin State of the BAND TX port to OOS,MT (ANSI) or Locked,maintenance
(ETSI) for the channel related to the wavelength selected on the tunable laser.
Verify that the Power value of the BAND TX port is higher than the default no-power value of
d.
–30 dBm.
Verify the west 4MD-xx.x card (west-to-east):
Step 9
Display the west 4MD-xx.x card in card view.
a.
Click the Provisioning > Optical Chn > Parameters tabs.
b.
c.
Verify that the Power value of the CHAN TX port is higher than the default no-power value of
–30 dBm.
Verify the west AD-xC-xx.x (west-to-east) card:
Step 10
Display the west AD-xC-xx.x card in card view.
a.
b.
If the AD-xC-xx.x card is an AD-4C-xx.x card, a VOA (applied to all four channels) is installed
along the drop path and needs to be activated according to Step g.
Click the Provisioning > Optical Chn > Parameters tabs.
c.
Verify that the Power value of the CHAN TX port is higher than the default no-power value of
d.
–35 dBm.
Display the east AD-xC-xx.x card in card view.
e.
Click the Provisioning > Optical Chn > Parameters tabs.
f.
Change the Admin State of the CHAN TX port related to the wavelength selected on the tunable
g.
laser or TXP_MR_2.5G card to OOS,MT (ANSI) or Locked,maintenance (ETSI). Click Apply.
Verify that the power value for the CHAN TX port is higher than the default no-power value of
h.
–35 dBm.
Perform the output power check.
i.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0