NTP-G25 Set Power Monitor Thresholds
NTP-G25 Set Power Monitor Thresholds
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
The default battery power thresholds are normally not changed. Threshold changes should only be
performed at the direction of your site administrator.
Complete the
Step 1
logged in, continue with Step 2.
In node view, click the Provisioning > General > Power Monitor tabs.
Step 2
To change the extreme low battery voltage threshold in 0.5 VDC increments, choose a voltage from the
Step 3
ELWBATVGVdc drop-down list.
To change the low battery voltage threshold in 0.5 VDC increments, choose a voltage from the
Step 4
LWBATVGVdc drop-down list.
To change the high battery voltage threshold in 0.5 VDC increments, choose a voltage from the
Step 5
HIBATVGVdc drop-down list.
Step 6
To change the extreme high battery voltage threshold in 0.5 VDC increments, choose a voltage from the
EHIBATVGVdc drop-down list.
Click Apply.
Step 7
Stop. You have completed this procedure.
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
3-10
This procedure provisions extreme high, extreme low, and low input
battery power thresholds within a –48 VDC environment. When the
thresholds are crossed, the TCC2/TCC2P generates warning alarms in
CTC. For ONS 15454 power specifications, see
Specifications."
None
NTP-G22 Verify Common Card Installation, page 3-4
Required
Onsite or remote
Provisioning or higher
"DLP-G46 Log into CTC" task on page 2-25
Chapter 3
Appendix B, "Hardware
for the node you will set up. If you are already
Turn Up a Node
September 2005