Table 11-22 32Wss Optical Channel Alarm Threshold Settings; Dlp- G213 Change The 32Wss Optical Channel Thresholds - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 11
Change DWDM Card Settings
Table 11-22
Parameter
Port
Power Failure
Low (dBm)
Power Degrade
High (dBm)
September 2005
32WSS Optical Channel Alarm Threshold Settings
Description
(Display only) Displays the port number.
For each optical channel (wavelength), two
logical ports are associated. Only one port
can be active at a time, depending on the
port's operating mode. The operating mode,
provisioned on the card view Maintenance
tab, is either Add Drop or Pass-Through.
Ports 1 through 32 (RX) are associated to
optical channels configured as Add Drop
channels. Ports 33 through 64 (PT) are
associated to optical channels configured as
Pass-Through channels.
Shows the power failure low threshold. This
power value applies to the corresponding
port and is automatically calculated when
ANS is run.
This threshold applies to a port associated to
a VOA (OSC-VOA) always active in
Constant Power mode.
The threshold is automatically linked to the
Power Setpoint (VOA Power Ref + VOA
Power Calib) provisioned. Changing the
setpoint results in changing the threshold
(always 5 dB lower).
The threshold is calculated automatically
when you run ANS. You can manually
change the threshold. The value must be
within the optical power range that is
specified for the card. (See
"Hardware
Specifications.")
Shows the power degrade high threshold.
This power value applies to the
corresponding port and is automatically
calculated when ANS is run.
This threshold applies to a port associated to
a VOA (OSC-VOA) always active in
Constant Power mode.
The threshold is automatically linked to the
Power Setpoint (VOA Power Ref + VOA
Power Calib) provisioned. Changing the
setpoint results in changing the threshold
(always 3 dB higher).
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
DLP-G213 Change the 32WSS Optical Channel Thresholds
Options
Display only
Numeric. Double-click the parameter,
enter a value, and press Enter.
Appendix B,
Display only
11-37

Advertisement

Table of Contents
loading

Table of Contents