Figure 16-14 Osc-Csm Optical Module Functional Block Diagram; Power Monitoring - Cisco ONS 15454 DWDM Installation And Operation Manual

Hide thumbs Also See for ONS 15454 DWDM:
Table of Contents

Advertisement

Chapter 16
Card Reference
Figure 16-14
Figure 16-14
Control
Interface

16.4.2.1 Power Monitoring

Physical photodiodes P1, P2, P3, and P5 monitor the power for the OSC-CSM card. Their function is as
follows:
The returned power level values are calibrated to the ports as shown in
April 2006
shows the OSC-CSM optical module functional block diagram.
OSC-CSM Optical Module Functional Block Diagram
DROP
section
PV1
V
LINE RX
Control
PV2
V
LINE TX
Filter
ADD
section
V
Virtual photodiode
P
Physical photodiode
Variable optical attenuator
Optical splitter
P1 and P2: The returned power value is calibrated to the LINE RX port, including the insertion loss
of the previous filter (the reading of this power dynamic range has been brought backward towards
the LINE RX output).
P3: The returned value is calibrated to the COM RX port.
P5: The returned value is calibrated to the LINE TX port, including the insertion loss of the
subsequent filter.
P1
S1
Filter
HW Switch
P5
Control
P
Opt. Switch
P
P
P4
P3
MON TX
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
16.4.2 OSC-CSM Card
MON RX
P
COM TX
OSC TX
P
P2
OSC RX
COM RX
S2
Table
16-18.
16-33