Chapter 3
Turn Up a Node
A terminal site has only one side (as compared to a hub node, which has two sides). The terminal
side can be either east or west.
The terminal side OPT-BST or OSC-CSM card COM TX port is connected to the terminal side
OPT-PRE COM RX port or the 32DMX-O COM RX port.
The terminal side OPT-PRE COM TX port is connected to the terminal side 32DMX-O COM RX
port.
The terminal side 32MUX-O COM TX port is connected to the terminal side OPT-BST or
OSC-CSM COM RX port.
Step 2
Plug one fiber cable end into the desired RX port.
Route the fiber cable on the card faceplate through the fiber clip on the faceplate, if provided. (Fiber clips
Step 3
are factory-attached to the faceplates of 32MUX-O, 32DMX-O, OSCM, OPT-PRE, and OPT-BST
cards.)
Route the fiber cable through the cable-routing channel and cutout on the appropriate side of the shelf
Step 4
assembly, as necessary
As needed, route slack fiber-optic cable around the round cable retainers in the fiber-storage tray
Step 5
(Figure 15-38 on page
When you close the fiber-storage tray, the cables must not be pinched, and the cable bend radius must
Caution
be equal to or greater than the minimum radius that is recommended in your site specifications. As you
route each cable through the fiber-storage tray, make sure that adequate cable slack remains.
Route the fiber cable out either side of the fiber-storage tray as necessary.
Step 6
Plug the other end of the cable into the desired TX port.
Step 7
Note
Repeat
Step 8
Return to your originating procedure (NTP).
Step 9
September 2005
(Figure 15-35 on page
15-40).
Cards display an SF LED after the OSC terminations are created (see the
OSC Terminations" procedure on page
correctly. For example, an RX port is connected to another RX port or a TX port is connected to
another TX port.
2
through
7
until you have connected the nodes according to the site plan.
DLP-G67 Install Fiber-Optic Cables for a Terminal Node
15-37).
3-84) if transmit and receive fibers are not connected
Cisco ONS 15454 DWDM Installation and Operations Guide, R6.0
"NTP-G38 Provision
3-57