3.9.1

Reset Levels

The reset operations of the MB91350A are classified into two levels, each of which has
different causes and initialization operations.
This section describes these reset levels.
■ Settings Initialization Reset (INIT)
The highest-level reset, which initializes all settings, is called a settings initialization reset (INIT).
A settings initialization reset (INIT) mainly performs the following initialization:
[Items initialized in a settings initialization reset (INIT)]
Device operation mode (bus mode and external bus width settings)
All internal clock settings (clock source selection, PLL control, and divide ratio setting)
All settings on external bus CS0 area
All settings on pin statuses other than the above settings
All sections initialized by an operation initialization reset (RST)
For more information, see the description of each for these functions.
After power-on, be sure to apply a settings initialization reset (INIT) at the INIT pin.
■ Operation Initialization Reset (RST)
A normal-level reset that initializes the operation of a program is called an operation initialization reset
(RST).
If a settings initialization reset (INIT) occurs, an operation initialization reset (RST) also occurs.
An operation initialization reset (RST) mainly initializes the following items:
[Items initialized by an operation initialization reset (RST)]
Program operation
CPU and internal buses
Register settings of peripheral circuits
I/O port settings
All CS0 area settings of external buses
For more information, see the description of each for these functions.