Fujitsu FR60 Hardware Manual page 107

Hide thumbs Also See for FR60:
Table of Contents

Advertisement

■ No-coprocessor Trap
If a coprocessor instruction using a coprocessor that is not installed is executed, a no-coprocessor trap
occurs.
[Operation]
1. SSP-4 → SSP
2. PS → (SSP)
3. SSP-4 → SSP
4. Address of next instruction → (SSP)
5. "0" → S flag
6. (TBR+3E0
■ Coprocessor Error Trap
If an error occurs while a coprocessor is being used and then a coprocessor instruction that operates on the
coprocessor is executed, a coprocessor error trap occurs.
[Operation]
1. SSP-4 → SSP
2. PS → (SSP)
3. SSP-4 → SSP
4. Address of next instruction → (SSP)
5. "0" → S flag
6. (TBR+3DC
■ Operation of RETI Instruction
The RETI instruction specifies return from the EIT processing routine.
[Operation]
1. (R15) → PC
2. R15+4 → R15
3. (R15) → PS
4. R15+4 → R15
The RETI instruction must be executed while the S flag is set to 0.
) → PC
H
) → PC
H
89