14.3
Input Capture Module
This section describes the overview of the input capture module, the configuration and
functions of registers, and module operation.
■ Overview of the Input Capture Module
The input capture module detects either or both of the rising and falling edges for an externally input signal
and stores the 16-bit free-running timer value set at that time in a register. The input capture module can
also generate an interrupt when an edge of the input signal is detected.
425