no green-mode eee tx-idle-time
Use this command to return the EEE idle time to the default value.
Format
no green-mode eee tx-idle-time
Mode
Interface Config

green-mode eee tx-wake-time

Use this command to configure the EEE mode transmit wake time for an interface or range of
interfaces. The wake time is in microseconds (0–65535). The transmit wake time is the
amount of time the switch must wait to go back to the ACTIVE state from the LPI state when
it receives a packet for transmission.
Note:
This command is not available on all systems, even if EEE mode is
supported.
Default
0
Format
green-mode eee tx-wake-time microseconds
Mode
Interface Config
no green-mode eee tx-wake-time
Use this command to return the EEE wake time to the default value.
Format
no green-mode eee tx-wake-time
Mode
Interface Config

green-mode eee-lpi-history sampling-interval

Use this command to configure global EEE LPI history collection interval for the system. The
value specified in this command is applied globally on all interfaces in the switch. The
sampling interval unit is seconds (30 – 36000).
Note:
The sampling interval takes effect immediately; the current and future
samples are collected at this new sampling interval.
Default
3600 seconds
Format
green-mode eee-lpi-history seconds
Mode
Global Config