Term
Description
History Control
The requested number of discrete time intervals over which data is to be saved. The range is 1 to
Buckets Requested
65535. The default is 50.
History Control
The number of discrete sampling intervals over which data shall be saved. This object is read-only.
Buckets Granted
The default is 10.
History Control
The interval in seconds over which the data is sampled. The range is 1 to 3600. The default is 1800.
Interval
History Control
The owner string associated with the history control entry. The default is monitorHistoryControl.
Owner
Command example:
(NETGEAR Switch) #show rmon collection history
Index
Interface
----------------------------------------------------------------------
1
1/0/1
2
1/0/1
3
1/0/2
4
1/0/2
5
1/0/3
6
1/0/3
7
1/0/4
8
1/0/4
9
1/0/5
10
1/0/5
11
1/0/6
12
1/0/6
13
1/0/7
14
1/0/7
15
1/0/8
16
1/0/8
17
1/0/9
18
1/0/9
19
1/0/10
--More-- or (q)uit
M6100 Series Switches
Interval
Requested
Samples
30
10
1800
50
30
50
1800
50
30
50
1800
50
30
50
1800
50
30
50
1800
50
30
50
1800
50
30
50
1800
50
30
50
1800
50
30
50
1800
50
30
50
Utility Commands
305
Granted
Owner
Samples
10
myowner
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl
10
monitorHistoryControl

Advertisement