Parameter
Description
High Capacity Alarm
The method of sampling the selected variable and calculating the value to be compared against
Sample Type
the thresholds. Possible types are absolute and delta. The default is absolute.
High Capacity Alarm
The absolute value (that is, the unsigned value) of the hcAlarmVariable statistic during the last
Absolute Value
sampling period. The value during the current sampling period is not made available until the
period is complete. This object is a 64-bit unsigned value that is Read-Only.
High Capacity Alarm
This object indicates the validity and sign of the data for the high capacity alarm absolute value
Absolute Alarm Status
object (hcAlarmAbsValueobject). Possible status types are valueNotAvailable, valuePositive, or
valueNegative. The default is valueNotAvailable.
High Capacity Alarm
High capacity alarm startup alarm that may be sent. Possible values are rising, falling, or
Startup Alarm
rising-falling. The default is rising-falling.
High Capacity Alarm
The lower 32 bits of the absolute value for threshold for the sampled statistic. The range is 0 to
Rising-Threshold
4294967295. The default is 1.
Absolute Value Low
High Capacity Alarm
The upper 32 bits of the absolute value for threshold for the sampled statistic. The range is 0 to
Rising-Threshold
4294967295. The default is 0.
Absolute Value High
High Capacity Alarm
This object indicates the sign of the data for the rising threshold, as defined by the objects
Rising-Threshold
hcAlarmRisingThresAbsValueLow and hcAlarmRisingThresAbsValueHigh. Possible values are
Value Status
valueNotAvailable, valuePositive, or valueNegative. The default is valuePositive.
High Capacity Alarm
The lower 32 bits of the absolute value for threshold for the sampled statistic. The range is 0 to
Falling-Threshold
4294967295. The default is 1.
Absolute Value Low
High Capacity Alarm
The upper 32 bits of the absolute value for threshold for the sampled statistic. The range is 0 to
Falling-Threshold
4294967295. The default is 0.
Absolute Value High
High Capacity Alarm
This object indicates the sign of the data for the falling threshold, as defined by the objects
Falling-Threshold
hcAlarmFallingThresAbsValueLow and hcAlarmFallingThresAbsValueHigh. Possible values are
Value Status
valueNotAvailable, valuePositive, or valueNegative. The default is valuePositive.
High Capacity Alarm
The index of the eventEntry that is used when a rising threshold is crossed. The range is 1 to
Rising Event Index
65535. The default is 1.
High Capacity Alarm
The index of the eventEntry that is used when a falling threshold is crossed. The range is 1 to
Falling Event Index
65535. The default is 2.
High Capacity Alarm
The number of times the associated hcAlarmVariable instance was polled on behalf of the
Failed Attempts
hcAlarmEntry (while in the active state) and the value was not available. This object is a 32-bit
counter value that is read-only.
High Capacity Alarm
The owner string associated with the alarm entry. The default is monitorHCAlarm.
Owner
High Capacity Alarm
The type of non-volatile storage configured for this entry. This object is read-only. The default is
Storage Type
volatile.