Link Debounce Commands

Link debouncing functions on a per-port basis on physical interfaces. After you configure link
debouncing, if the switch receives a link-down notification, the switch starts monitoring the
link event by starting a timer with the configured debounce time. Any intermediate link-down
and link-up events are ignored hereafter. When the timer expires, link debounce checks if the
current state of the link is still down; if so, it forwards a link-down notification to the upper
layer applications.
You must explicitly enable link debounce per interface with an appropriate debounce timer
value, taking into consideration the network topology and the features enabled on the switch,
such as LAG or spanning tree.
Note:
Link debouncing is disabled by default.
debounce-time
This command configures the debounce time. The possible values for the milliseconds
parameter are in the 100–5000 range.
Format
debounce-time milliseconds
Mode
Interface Config
No debounce-time
This command disables the debounce time.
Format
no debounce-time
Mode
Interface Config

show interface debounce

This command displays the flap counts for all interfaces.
Format
show interface debounce
Mode
Privileged EXEC
Command example:
(NETGEAR Switch) #show interface debounce
Interface Debounce Time(ms)
--------- --------------
1/0/1
0
1/0/2
0
M6100 Series Switches
Flaps
-------
0
0
Switching Commands
582