no dot1x system-auth-control
This command is used to disable the dot1x authentication support on the switch.
Format
no dot1x system-auth-control
Mode
Global Config

dot1x system-auth-control monitor

Use this command to enable the 802.1X monitor mode on the switch. The purpose of Monitor
mode is to help troubleshoot port-based authentication configuration issues without
disrupting network access for hosts connected to the switch. In Monitor mode, a host is
granted network access to an 802.1X-enabled port even if it fails the authentication process.
The results of the process are logged for diagnostic purposes.
Default
disabled
Format
dot1x system-auth-control monitor
Mode
Global Config
no dot1x system-auth-control monitor
This command disables the 802.1X Monitor mode on the switch.
Format
no dot1x system-auth-control monitor
Mode
Global Config

dot1x timeout

This command sets the value, in seconds, of the timer used by the authenticator state
machine on an interface or range of interfaces. Depending on the token used and the value
(in seconds) passed, various timeout configurable parameters are set. The following tokens
are supported:
Tokens
Definition
guest-vlan-period
The time, in seconds, for which the authenticator waits to see if any EAPOL packets are received on
a port before authorizing the port and placing the port in the guest vlan (if configured). The guest
vlan timer is only relevant when guest vlan has been configured on that specific port.
reauth-period
The value, in seconds, of the timer used by the authenticator state machine on this port to determine
when reauthentication of the supplicant takes place. The reauth-period must be a value in the range
1 - 65535.
quiet-period
The value, in seconds, of the timer used by the authenticator state machine on this port to define
periods of time in which it will not attempt to acquire a supplicant. The quiet-period must be a value
in the range 0 - 65535.