falling utilization threshold is optional. If the falling CPU utilization parameters are not
configured, then they take the same value as the rising CPU utilization parameters.
Format
process cpu threshold type total rising threshold interval seconds [falling
threshold interval seconds]
Mode
Global Config
Parameter
Description
rising threshold
The percentage of CPU resources that, when exceeded for the configured rising interval, triggers a
notification. The range is 1 to 100. The default is 0 (disabled).
rising interval
The duration of the CPU rising threshold violation, in seconds, that must be met to trigger a
notification. The range is 5 to 86400. The default is 0 (disabled).
seconds
falling threshold
The percentage of CPU resources that, when usage falls below this level for the configured interval,
triggers a notification. The range is 1 to 100. The default is 0 (disabled).
A notification is triggered when the total CPU utilization falls below this level for a configured period
of time. The falling utilization threshold notification is made only if a rising threshold notification was
previously done. The falling utilization threshold must always be equal or less than the rising
threshold value. The CLI does not allow setting the falling threshold to be greater than the rising
threshold.
falling interval
The duration of the CPU falling threshold, in seconds, that must be met to trigger a notification. The
range is 5 to 86400. The default is 0 (disabled).
seconds