Command example:
(NETGEAR Switch) (Config)# rmon hcalarm 1 ifInOctets.1 30 absolute rising-threshold high
1 low 100 status positive 1 falling-threshold high 1 low 10 status positive startup
rising owner myOwner
no rmon hcalarm
This command deletes the rmon hcalarm entry.
Format
no rmon hcalarm alarm-number
Mode
Global Config
Command example:
(NETGEAR Switch) (Config)# no rmon hcalarm 1

rmon event

This command sets the RMON event entry in the RMON event MIB group.
Format
rmon event event-number [description string | event-type | owner string |
trap community]
Mode
Global Config
Parameter
Description
Event Index
An index that uniquely identifies an entry in the event table. Each such entry defines one event that
is to be generated when the appropriate conditions occur. The range is 1 to 65535.
Event Description
A comment describing the event entry. The default is alarmEvent.
Event Type
The type of notification that the probe makes about the event. Possible values are None, Log, SNMP
Trap, Log and SNMP Trap. The default is None.
Event Owner
Owner string associated with the entry. The default is monitorEvent.
Event Community
The SNMP community specific by this octet string which is used to send an SNMP trap. The default
is public.
Command example:
(NETGEAR Switch) (Config)# rmon event 1 log description test