Known Backsight Point - Leica TPS1200 series Technical Reference Manual

Hide thumbs Also See for TPS1200 series:
Table of Contents

Advertisement

45.6.3
Requirements
Access step-by-step
Setup

Known Backsight Point

For TPS1200 the position coordinates of the station point are required. The instrument is
set up and oriented to a known backsight target.
For SmartStation the position coordinates of the station are unknown and are determined
with GPS real-time. The instrument is set up and oriented to a known backsight target.
Refer to the stated chapter for more information on screens.
Description
1.
Press PROG to access the Programs menu.
2.
Select and activate Setup to move to the first screen.
3.
Press CONT (F1) to access SETUP Station Setup.
4.
<Method:> Ensure that Known BS Point is selected.
<Station Coord:> Select the source for the instrument station coordinates.
<Station ID:> Enter/Select the instrument station.
<Instrument Ht:> Enter the height of the instrument station.
<Fixpoint Job:> Select the fixpoint job of the control/target points.
5.
The geometric scale correction is displayed.
The correction displayed depends upon the options chosen in CONFIGURE
TPS Corrections, GeoPPM page:
• if <Calc Scale: Automatically>, <Computd Scale:> is displayed.
• if <Calc Scale: Manually>, <Current Scale:> is displayed.
TPS1200
Refer to
chapter
17.4
1125