Leica TPS1200 series Technical Reference Manual page 936

Hide thumbs Also See for TPS1200 series:
Table of Contents

Advertisement

Hidden Point
Description of fields
Field
<Display Mask:>
<Meas Tolerance:>
<Delete Aux Points:> Yes or No
<No. of Refectors:>
<Auto Position:>
<Rod Length:>
<Dist R1-R2:>
TPS1200
Option
Description
Choicelist
The user defined display mask to be shown in
HIDDEN PT Measure Reflector n. All display masks
of the active configuration set defined in
CONFIGURE Display Settings can be selected.
User input
Limit of the difference between input and measured
spacing of the reflectors.
For three reflectors being used, limit for
maximum deviation of the three measure-
ments.
The auxiliary points are deleted when the hidden
point is stored.
The auxiliary points are reflector 1, reflector 2 and
reflector 3 of the hidden point rod.
The Auxiliary Points ID template is used for the auxil-
iary points. The Survey Points ID template is used for
the computed hidden point.
2 or 3
Two or three reflectors are used on the rod.
Yes or No
Available for <No. of Reflectors: 3>. The third
reflector is aimed at automatically.
User input
Total length of hidden point rod.
User input
Spacing between the centres of reflector 1 and
reflector 2.
936

Advertisement

Table of Contents
loading

Table of Contents