45.7
45.7.1
Description
Access
SETUP
Results,
Stn Coords page
Setup

Setup Results

Least Square and Robust Calculation

This screen is displayed after a resection or orientation and height transfer calculation.
For the calculations the least square or the robust method can be used. After the station
is set, all following measurements will be related to this new station and orientation.
Press CALC (F5) in the SETUP Measure Target screen.
The screen described consists of the Stn Coords, Sigma, Stn Code and Plot page. The
explanations for the softkeys given below are valid for the Stn Coords and Sigma page.
Refer to "6.3.2 Creating a New Point" for information on the keys on the Stn Code page refer
to "34.6 Plot Mode - MapView Screen Area" for information on the keys on the Plot page.
SET (F1)
To set data selected in
setup data and exit the application
program.
COORD (F2)
To view other coordinate types.
ROBST (F3) or LSQRS (F3)
To display the results for the robust or the
least squares calculation method.
TPS1200
<
and to store all
Set:>