Survey - General
TEST (F5)
To access the SURVEY EDM Test
Signal/Frequency screen. Available for <EDM
Mode: Tracking> and/or <Log Auto Pts:
Yes>, after the tracking or logging is started.
SHIFT CONF (F2)
To configure auto points and remote point
measurements. Accesses SURVEY Configu-
ration. When SHIFT AVGE (F2) or SHIFT
ABS (F2) are active, this key is not available.
Refer to "48 Survey - Auto Points" and to "49
Survey - Remote Point" for information on the
fields and keys.
SHIFT AVGE (F2)
To check the residuals for the averaged point.
Available for <Averaging Mode: Average>
and for more than one measured coordinate
triplet recorded for the same point. Refer to
"6.3.4 Mean Page".
SHIFT ABS (F2)
To check the absolute difference between the
measurements. Available for <Averaging
Mode: Absolute Diffs> and for more than one
measured coordinate triplet recorded for the
same point. Refer to "6.3.4 Mean Page".