Leica TPS-System1100 Set Up And Shut Down Instructions

Leica TPS-System1100 Set Up And Shut Down Instructions

Electronic distance measuring

Advertisement

Quick Links

EDM
Electronic Distance Measuring
Athletics Measurement Setup Manual
For
Leica
TPS-System1100
TPS-System 1200
Viva TS15
Simple set up and shut down instructions.
Note: The operation of the EDM for each individual event is not included in this document.
C:\Neil\Athletics\EDM\EDM setup instructions.docx
02/03/2017
1

Advertisement

loading

Summary of Contents for Leica TPS-System1100

  • Page 1 Electronic Distance Measuring Athletics Measurement Setup Manual Leica TPS-System1100 TPS-System 1200 Viva TS15 Simple set up and shut down instructions. Note: The operation of the EDM for each individual event is not included in this document. C:\Neil\Athletics\EDM\EDM setup instructions.docx 02/03/2017...
  • Page 2 Prepared by Jenny Boardman and Neil Rogers 1. The EDM kit contains. Leica EDM (models- System 1100, System 1200 and Viva TS15 may vary between states), Tripod, 2 charged batteries, Accessories (1x check marker, 1x metal tape measure, 1x small hand-held spirit level, 3x non-slip...
  • Page 3 3. Tripod setup for Jumping events. (fig. 3) Position the EDM in a safe location where the safety of the operator and apparatus will not be compromised, Set up in clear sight of take-off boards and landing area on the opposite side of the take-off board from the pit, and in accordance with the requests of the Referee/Chief, Set height of tripod top at chest height of the intended operator.
  • Page 4 top of the tripod, Check and adjust the 3 levelling screws to be at mid-height of their travel, Adjust the 3 levelling screws so the level bubble on the instrument is central, 6. Turn on EDM instrument. Turn on and wait for Main Menu to load, Check battery status, “Protocols for use of the memory card are yet to be developed”, Set digital level...
  • Page 5 athlete and/or age group) Javelin 9.1.1 Measure ‘centre’ point Set prism at 8m intersection of sector lines ‘Distance’ press F2 9.1.2 ‘Store’ press F3 9.1.3 ‘Done’ wait for ‘Done’ to appear then press F4 9.1.4 Measure ‘Distance’ Set prism on check marker located inside the sector press F2 9.1.5 ‘Store’...
  • Page 6 9.5.10 Check measurement to the check marker with metal tape by Referee/Chief Note: The above setups are based on the assumption that each athletics officials organisation has taken the appropriate steps to locate and clearly mark the centres of all throwing sectors and the 8m mark for javelin prior to any competition and preferably prior to the commencement of the athletics season.
  • Page 7 14.3 Simply return to ‘Main Menu’ by constantly hitting the; ‘Escape’ Key (System 1100, 1200), ‘Return’ key (Viva TS15), 14.4 You will be asked; “do you want to exit without storing the last measurement?” Select “YES” 14.5 Continue to hit the Escape / Return key till reaching the ‘Main Menu’, 14.6 Re-enter the event being interrupted, (refer to section 9.0.1 and 9.0.3),...

This manual is also suitable for:

Tps-system 1200Viva ts15