Stakeout
STAKEOUT
Configuration,
Heights page
Next step
PAGE (F6) changes to the Heights page. Refer to paragraph "STAKEOUT Configuration,
Heights page".
Description of fields
Field
Option
<Height Offset:>
User input
<Edit Height:>
Yes
No
<Use DTM:>
No
TPS1200
Description
Allows a constant height offset to be applied to the
height of the points or DTM being staked.
The field <D Ht:> for the design height is displayed in
STAKEOUT Orthogonal Stakeout, Stake page and
STAKEOUT Polar Stakeout, Stake page. The
design height is the height of the point to be staked.
The value for <D Ht:> can be changed.
The field <Ht:> for the height of the current position is
displayed in STAKEOUT Orthogonal Stakeout,
Stake page and STAKEOUT Polar Stakeout, Stake
page. The value for <Ht:> cannot be changed.
Available if DTM Stakeout has been activated via a
licence key. Refer to "28 Tools...\Licence Keys" for
information on how to type in or upload the licence
key. Available unless STAKEOUT Configuration,
Heights page was accessed while being within the
Stakeout application program.
No DTM file is used. The positions and heights of
points in the selected <Stakeout Job:> are staked
out.