Traverse
Step
Description
9.
TRAVERSE Foresight, Set:X/X
<Foresight ID:> The name of the foresight point.
<Reflector Ht:> The reflector height of the foresight point.
<No. of Sets:> The number of sets to be measured.
DONE (F4) available for <Foresight: Multiple> to stop measuring
further foresight points.
SURVY (F5) to measure sideshot points.
SHIFT GETPT (F4) to get a point from the <Fixpoint Job:> to be
used as closing point, check point or normal foresight point.
10.
ALL (F1) to measure and record. The measurement settings for the
first measurement to each point are used for all further sets.
11.
Repeat step 10. until all sets are measured.
12.
TRAVERSE Point Statistics, Pt: X/X
13.
CONT (F1) to choose to move to the next station, to measure a side-
shot point, to view traverse data or to end traverse.
SURVY (F3) to measure a sideshot point.
DATA (F5) to view traverse data.
END T (F6) to end traverse.
14.
MOVE (F1) to move to the next station.
TPS1200
1284
Refer to
chapter
51.5
51.5

Advertisement