Measuring Hidden Points - Leica TPS1200 series Technical Reference Manual

Hide thumbs Also See for TPS1200 series:
Table of Contents

Advertisement

Hidden Point
41.4
Diagram
Measuring hidden point
step-by-step

Measuring Hidden Points

P0
TPS12_127
Step
Description
1.
Refer to "41.2 Accessing Hidden Point" to access HIDDEN PT
Hidden Point Begin.
2.
CONF (F2) to access HIDDEN PT Configuration.
3.
HIDDEN PT Configuration
<No. of Reflectors: 3>
Enter the values for <Rod Length:>, <Dist R1-R2:>, <Dist R1-R3:>
4.
CONT (F1) to access HIDDEN PT Hidden Point Begin.
5.
HIDDEN PT Hidden Point Begin
CONT (F1) to access HIDDEN PT Measure Reflector 1
TPS1200
1
d3
d2
3
d1
2
d1
P1
d2
d3
Rod length
Distance from reflector 1 to reflector 2
Distance from reflector 1 to reflector 3