Reference Plane & Face Scan
Step
Description
DEL (F4) to remove the highlighted point from the list.
SURVY (F5) to measure a point to be used for the plane.
DONE (F4) to return to REFPLANE New Reference Plane.
SHIFT ORIGN (F4) to use the highlighted point as the origin of the
plane.
8.
PAGE (F6) to change to the Origin page.
9.
REFPLANE New Reference Plane, Origin page.
<Use As Origin: Plane Coords> Point results are additionally stored
with X, Y, Z coordinates based on the local plane coordinate system.
<Use As Origin: Instrumnt Coords> Points on the plane have
instrument coordinates.
<X-coord:> Available for <Use As Origin: Plane Coords>. Enter
local X coordinate of origin. The origin is defined as the projection of
the measured point onto the calculated plane.
<Z-coord:> Available for <Use As Origin: Plane Coords>. Enter
local Z coordinate of origin. The origin is defined as the projection of
the measured point onto the calculated plane.
<Point:> Defines the positive direction of the Y axis.
DIREC (F5) Available for <Point:> being hightlighted. To access
REFPLANE Survey: XX. Measure a point to define the positive plane
direction.
10.
PAGE (F6) to change to the Offset page.
TPS1200
1042
Refer to
chapter

Advertisement