8.5
Access
Description
8.6
Description
Access

Backsight Check

FlexLine plus, Favourites

EDM Tracking

1.
Press the FNC/Favourites key when within any program.
2.
Select
EDM Track from the Favourites Menu.
This favourite activates or deactivates the tracking measurement mode. The new
setting is displayed for about one second and then set. This favourite can only be acti-
vated from within the same EDM mode and prism type. The following options are avail-
able.
EDM Mode
Tracking mode OFF! <=> Tracking mode ON!
Prism
Precise+ <=> Tracking / Precise&Fast <=> Tracking
Non-Prism
NP-Precise <=> NP-Tracking
The last active measurement mode remains set when the instrument is switched off.
Backsight Check
This favourite enables the user to remeasure to the point(s) used for Station Setup.
This is useful to check if the station position is still correct after measuring some
points.
1.
Press the FNC/Favourites key when within any program.
2.
Select
BS-Check from the Favourites Menu.
This screen is exactly the same as the Stakeout screen, except that the available PtIDs
are restricted to the points used for the last orientation. Refer to "7.4 Stakeout" for
information about the screen.
When setting up a station by local resection, check the coordinate system of the
points used from the list.